Schneider Electric

Schneider Electric LC1D50A3BD IEC contactor, TeSys Deca, nonreversing, 50A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D50A3BD
MPN:
LC1D50A3BD
Condition:
New
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Width:
55 mm
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Protective Cover:
with
Reach Free Of Svhc:
Yes
Flame Retardance:
V1 conforming to UL 94
Mounting Support:
rail || plate
Pole Contact Composition:
3 NO
Protective Treatment:
THIEC 60068-2-30
Sustainable Offer Status:
Green Premium product
Pvc Free:
Yes
Utilisation Category:
AC-4 || AC-1 || AC-3 || AC-3e
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Maximum Horse Power Rating:
3 hp at 115 V AC 50/60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 40 hp at 460/480 V AC 50/60 Hz for 3 phase
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Fire Resistance:
850°C IEC 60695-2-1
Height:
122 mm
Connections - Terminals:
control circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
[Ie] Rated Operational Current:
50 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Compatibility Code:
LC1D
Net Weight:
0.93 kg
[Uc] Control Circuit Voltage:
24 V DC
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Ip Degree Of Protection:
IP20 front face IEC 60529
Eu Rohs Directive:
Compliant
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Operating Altitude:
0...9842.52 ft (0...3000 m)
Pollution Degree:
3
Range:
TeSys || TeSys Deca
Circularity Profile:
ENVEOLI1503009EN
Electrical Durability:
1.45 Mcycles 50 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V || 1.45 Mcycles 50 A AC-3e <= 440 V
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mercury Free:
Yes
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Signaling Circuit Frequency:
25...400 Hz
Contactor Application:
resistive load || motor control
Environmental Disclosure:
ENVPEP1503009EN
Insulation Resistance:
> 10 MOhm for Signaling circuit
Auxiliary Contact Composition:
1 NO + 1 NC
Minimum Switching Current:
5 mA for Signaling circuit
Inrush Power In W:
19-19 W 20°C)
Rohs Exemption Information:
Yes
$306.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.05 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose