Schneider Electric

Schneider Electric LC1D95BD IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D95BD
MPN:
LC1D95BD
Condition:
New
Ip Degree Of Protection:
IP20 front face IEC 60529
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Safety Reliability Level:
B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 || B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Overvoltage Category:
III
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.85...1.1 Uc -40-55°C operational DC || 1...1.1 Uc 55-70°C operational DC
Eu Rohs Directive:
Compliant
Toxic Heavy Metal Free:
Yes
Net Weight:
2.61 kg
Electrical Durability:
1.2 Mcycles 95 A AC-3 || 1.3 Mcycles 125 A AC-1 || 1.2 Mcycles 95 A AC-3e
[Ie] Rated Operational Current:
95 A (at <60°C) at <= 440 V AC-3 for power circuit || 125 A (at <60°C) at <= 690 V AC-1 for power circuit || 95 A (at <60°C) at <= 440 V AC-3e for power circuit
Protective Treatment:
THIEC 60068-2-30
Fire Resistance:
850°C IEC 60695-2-1
Pole Contact Composition:
3 NO
Warranty:
18 months
Device Short Name:
LC1D
Signaling Circuit Frequency:
25...400 Hz
Coil Technology:
without built-in suppressor module
Pvc Free:
Yes
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Protective Cover:
with
Climatic Withstand:
IACS E10 exposure to damp heat
Range:
TeSys
Hold-In Power Consumption In W:
22-22 W 20°C
Time Constant:
75 ms
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.
Height:
127 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Operating Time:
95...130 ms closing || 20...35 ms opening
Environmental Disclosure:
ENVPEP110205EN
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Icw] Rated Short-Time Withstand Current:
1100 A 40°C - 1 s for power circuit || 800 A 40°C - 10 s for power circuit || 400 A 40°C - 1 min for power circuit || 135 A 40°C - 10 min for power circuit || 140 A - 100 ms for Signaling circuit || 120 A - 500 ms for Signaling circuit || 100 A - 1 s
Inrush Power In W:
22-22 W 20°C)
Flame Retardance:
V1 conforming to UL 94
Maximum Horse Power Rating:
7.5 hp at 120 V AC 60 Hz for 1 phase motors || 15 hp at 230/240 V AC 60 Hz for 1 phase motors || 30 hp at 200/208 V AC 60 Hz for 3 phase motors || 30 hp at 230/240 V AC 60 Hz for 3 phase motors || 60 hp at 460/480 V AC 60 Hz for 3 phase motors || 60
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Depth:
186 mm
Country of Origin:
Czechia
Pollution Degree:
3
Product Certifications:
IECEE CB Scheme || CCC || EAC || LROS (Lloyds register of shipping) || RINA || BV || DNV-GL
Auxiliary Contact Composition:
1 NO + 1 NC
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Compatibility Code:
LC1D
Product Or Component Type:
contactor
Minimum Switching Current:
5 mA for Signaling circuit
Circularity Profile:
N/A
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
$526.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 7.32 inches deep. It weighs 5.75 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose