Schneider Electric LC1DT60AG7 IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style
Schneider Electric
$353.16
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 120 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
- Pole Contact Composition:
- 4 NO
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Width:
- 70 mm
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Electrical Durability:
- 1.4 Mcycles 60 A AC-1 <= 440 V
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Protective Cover:
- with
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Contactor Application:
- resistive load
- Product Or Component Type:
- contactor
- Mounting Support:
- rail || plate
- Depth:
- 120 mm
- Power Dissipation Per Pole:
- 5.8 W AC-1
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
- Pollution Degree:
- 3
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C)
- Tightening Torque:
- control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BT
- Sustainable Offer Status:
- Green Premium product
- Rohs Exemption Information:
- Yes
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Net Weight:
- 1.09 kg
- Coil Technology:
- without built-in suppressor module
- Flame Retardance:
- V1 conforming to UL 94
- Warranty:
- 18 months
- Control Circuit Type:
- AC 60 Hz
- Mercury Free:
- Yes
- Fire Resistance:
- 850°C IEC 60695-2-1
- Average Impedance:
- 1.6 mOhm - Ith 60 A 50 Hz for power circuit
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Environmental Disclosure:
- ENVPEP1503009EN
- Circularity Profile:
- ENVEOLI1503009EN
- Rated Breaking Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- Protective Treatment:
- THIEC 60068-2-30
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- [Uc] Control Circuit Voltage:
- 120 V AC 60 Hz
- Pvc Free:
- Yes
- Poles Description:
- 4P
- Range:
- TeSys || TeSys Deca
- Reach Free Of Svhc:
- Yes
- Product Certifications:
- RINA || CSA || GOST || LROS (Lloyds register of shipping) || DNV || CCC || UL || GL || BV
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- [Icw] Rated Short-Time Withstand Current:
- 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Overvoltage Category:
- III
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Signaling Circuit Frequency:
- 25...400 Hz