Schneider Electric

Schneider Electric LC1G2654EHEA Contactor, high power, TeSys Giga, advanced version, AC-1, <= 440V, 385A, 4 pole/NO, 48-130VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G2654EHEA
MPN:
LC1G2654EHEA
Condition:
New
Pole Contact Composition:
4 NO
Net Weight:
8.7 kg
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Short Name:
LC1G
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Operating Time:
40...70 ms closing || 15...50 ms opening
Range:
TeSys
[Uimp] Rated Impulse Withstand Voltage:
8 kV
[Ui] Rated Insulation Voltage:
1000 V
Ambient Air Temperature For Storage:
-60-80°C
Mounting Support:
plate
Weight:
8.7 kg
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1 || UL 60335-1 || UL 60335-2-40:Annex JJ
Contactor Application:
power switching
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Associated Fuse Rating:
315 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 400 A gG at <= 690 V
Hold-In Power Consumption In W:
9.0-9.0 W
Inrush Power In W:
360 W
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
[Icw] Rated Short-Time Withstand Current:
2.2 kA - 10 s || 1.23 kA - 30 s || 0.95 kA - 1 min || 0.62 kA - 3 min || 0.48 kA - 10 min
Maximum Horse Power Rating:
75 hp at 200/208 V 60 Hz || 100 hp at 230/240 V 60 Hz || 200 hp at 460/480 V 60 Hz || 200 hp at 575/600 V 60 Hz
Inrush Power In Va:
430-430 VA
Eu Rohs Directive:
Compliant with Exemptions
Pvc Free:
Yes
Tightening Torque:
35 N.m
Power Dissipation Per Pole:
20 W AC-1 - Ith 385 A || 11 W AC-3 - Ith 265 A
Environmental Disclosure:
ENVPEP2105013
Coil Technology:
built-in bidirectional peak limiting
Compatibility Code:
LC1G
Mechanical Durability:
8 Mcycles
Rated Breaking Capacity:
2380 A at 440 V
Sustainable Offer Status:
Green Premium product
Circularity Profile:
ENVEOLI2105013
Rohs Exemption Information:
Yes
Poles Description:
4P
Average Impedance:
0.000144 Ohm
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms Rated Making Capacity:
3320 A at 440 V
Height:
290 mm
[Ith] Conventional Free Air Thermal Current:
385 A (at 40°C)
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1
Country of Origin:
China
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Mercury Free:
Yes
Halogen Content Performance:
Halogen free plastic parts product
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
[Ie] Rated Operational Current:
265 A (at <60°C) at <= 440 V AC-3 || 385 A (at <40°C) at <= 1000 V AC-1
$2,050.00

Description

TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 385A @440V. It provides a 48-130V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 185mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
View AllClose