Schneider Electric LC1G330KUEN Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 330A, 100-250VAC/DC coil

(No reviews yet) Write a Review
SKU:
LC1G330KUEN
MPN:
LC1G330KUEN
Condition:
New
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8a || AC-8b || DC-1 || DC-3 || DC-5
Device Short Name:
LC1G
Range Of Product:
TeSys Giga
Product Certifications:
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Coil Technology:
built-in bidirectional peak limiting
Compatibility Code:
LC1G
Connections - Terminals:
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control
[Ie] Rated Operational Current:
440 A (at <40°C) at <= 1000 V AC-1 || 330 A (at <60°C) at <= 440 V AC-3
Tightening Torque:
35 N.m
Maximum Horse Power Rating:
100 hp at 200/208 V 60 Hz || 125 hp at 230/240 V 60 Hz || 250 hp at 460/480 V 60 Hz || 300 hp at 575/600 V 60 Hz
Maximum Operating Rate:
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Motor Power Kw:
90 kW at 230 V AC 50/60 Hz (AC-3e) || 160 kW at 400 V AC 50/60 Hz (AC-3e) || 160 kW at 415 V AC 50/60 Hz (AC-3e) || 185 kW at 440 V AC 50/60 Hz (AC-3e) || 200 kW at 500 V AC 50/60 Hz (AC-3e) || 220 kW at 690 V AC 50/60 Hz (AC-3e) || 185 kW at 1000 V
Hold-In Power Consumption In W:
9.1-9.1 W
Mechanical Robustness:
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Power Dissipation Per Pole:
30 W AC-1 - Ith 440 A || 16 W AC-3 - Ith 330 A
Irms Rated Making Capacity:
3830 A at 440 V
Operating Time:
40...70 ms closing || 15...50 ms opening
Ambient Air Temperature For Storage:
-60-80°C
[Ue] Rated Operational Voltage:
<= 1000 V AC 50/60 Hz || <= 460 V DC
Average Impedance:
0.000144 Ohm
Sustainable Offer Status:
Green Premium product
Mounting Support:
plate
Product Or Component Type:
contactor
Range:
TeSys
Environmental Disclosure:
ENVPEP2105013
Auxiliary Contact Composition:
1 NO + 1 NC
Control Circuit Voltage Limits:
operational: 0.8 Uc Min...1.1 Uc Max (at <60°C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60°C)
Overvoltage Category:
III
Net Weight:
7.5 kg
Mechanical Durability:
8 Mcycles
Eu Rohs Directive:
Compliant with Exemptions
Connection Pitch:
45 mm
[Ui] Rated Insulation Voltage:
1000 V
[Icw] Rated Short-Time Withstand Current:
2.65 kA - 10 s || 1.8 kA - 30 s || 1.3 kA - 1 min || 0.9 kA - 3 min || 0.75 kA - 10 min
China Rohs Regulation:
X
Contactor Application:
power switching || motor control
Hold-In Power Consumption In Va:
15.0-15.0 VA
Safety Reliability Level:
B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Ip Degree Of Protection:
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Pvc Free:
Yes
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
Inrush Power In Va:
700-700 VA
$1,495.00

Description

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 330A 200kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.