Schneider Electric

Schneider Electric LC1K1201B7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NC aux., 24VAC coil

(No reviews yet) Write a Review
SKU:
LC1K1201B7
MPN:
LC1K1201B7
Condition:
New
[Icw] Rated Short-Time Withstand Current:
115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
[Uc] Control Circuit Voltage:
24 V AC 50/60 Hz
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Auxiliary Contacts Type:
instantaneous 1 NC
Warranty:
18 months
Width:
45 mm
Sustainable Packaging:
Yes
Operating Altitude:
6561.68 ft (2000 m) without derating
Rohs Exemption Information:
Yes
Maximum Operating Rate:
3600 cyc/h
Eu Rohs Directive:
Compliant
Minimum Switching Current:
5 mA for Signaling circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Country of Origin:
Indonesia
Irms Rated Making Capacity:
144 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Device Short Name:
LC1K
Range:
TeSys
Mechanical Durability:
10 Mcycles
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Electrical Durability:
1.3 Mcycles 12 A AC-3 <= 440 V || 1.3 Mcycles 12 A AC-3e <= 440 V || 0.3 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 72 A AC-4 <= 440 V
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Free Of Svhc:
Yes
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Contactor Application:
resistive load || motor control
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
Sustainable Offer Status:
Green Premium product
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Auxiliary Contact Composition:
1 NC
Pole Contact Composition:
3 NO
[Uimp] Rated Impulse Withstand Voltage:
8 kV
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure:
ENVPEP1503003EN
Heat Dissipation:
1.3-1.3 W
Rated Breaking Capacity:
110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Circularity Profile:
ENVEOLI1503003EN
[Ie] Rated Operational Current:
12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Control Circuit Type:
AC 50/60 Hz
Device Application:
control
Insulation Resistance:
> 10 MOhm for Signaling circuit
Depth:
57 mm
Inrush Power In Va:
30-30 VA (at 20°C)
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Non Overlap Distance:
0.5 mm
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
$86.00

Description

LC1K1201B7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 24V 50/60Hz AC coil and 1NC auxiliary contact. LC1K1201B7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 24V 50/60Hz AC coil and 1NC built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NC built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
View AllClose