ABB MS132-1.6 Manual Motor Starter 1.0 ... 1.6 A

(No reviews yet) Write a Review
SKU:
MS132-1.6
MPN:
MS132-1.6
Condition:
New
Availability:
In our warehouse: 2
$215.67

Description

The MS132-1.6 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 1.60 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.

General Information

Extended Product Type: MS132-1.6
Product ID: 1SAM350000R1006
EAN: 4013614400063
Catalog Description: MS132-1.6 Manual Motor Starter 1.0 ... 1.6 A

Popular Downloads

Data Sheet, Technical Information: 2CDC131021D0202
Instructions and Manuals: 2CDC131022M6802
Instructions and Manuals (Part 2): 2CDC131060M0202
Ex Operating Instructions: 2CDC131063M6801
Time-Current Characteristic Curve: 1SAM300505F0106
I²t Characteristic: 1SAM300507F00011SAM300507F0003
Cut-off Current Characteristic: 1SAM300508F00011SAM300508F0003
CAD Dimensional Drawing: 2CDC001079B0201
Dimension Diagram: 1SAM300402F0001

Dimensions

Product Net Width: 45 mm
Product Net Height: 90 mm
Product Net Depth / Length: 86.75 mm
Product Net Weight: 0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
  • (230 V AC) 100 kA
  • (250 V DC) 3 Poles in Series 10 kA
  • (400 V AC) 100 kA
  • (440 V AC) 100 kA
  • (500 V AC) 100 kA
  • (690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
  • (230 V AC) 100 kA
  • (400 V AC) 100 kA
  • (440 V AC) 100 kA
  • (500 V AC) 100 kA
  • (690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii): 20 ASetting Range: 1.0 ... 1.6 A
Rated Operational Power AC-3 (Pe): (400 V) Three Phase 0.55 kW
Rated Operational Power AC-3e (Pe): (400 V) Three Phase 0.55 kW
Rated Operational Voltage: Main Circuit 690 V AC; Main Circuit 250 V DC
Rated Operational Current (Ie): 1.6 A
Rated Operational Current AC-3 (Ie): 1.6 A
Rated Operational Current AC-3e (Ie): 1.6 A
Rated Operational Current DC-5 (Ie): 1.6 A
Rated Frequency (f): Main Circuit 50 Hz; Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Main Circuit 6 kV
Rated Insulation Voltage (Ui): 690 V
Power Loss: at Rated Operating Conditions per Pole 0.6 ... 1.7 W
Number of Poles: 3
Conventional Free-air Thermal Current (Ith): Main Circuit 1.6 A
Degree of Protection: Housing IP20; Main Circuit Terminals IP10
Pollution Degree: 3
Electrical Durability: 50000 cycle
Mechanical Durability: 100000 cycle
Terminal Type: Screw Terminals
Connecting Capacity Main Circuit:
  • Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible 1/2x 0.75 ... 2.5 mm²
  • Rigid 1/2x 1 ... 4 mm²
Tightening Torque: Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length: Main Circuit 9 mm
Recommended Screw Driver: Pozidriv 2
Mounting Position: 1 ... 6
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715; TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715Minimum Mounting Distance:
  • Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
  • Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
  • Electrical Conductive Board, Vertical 75 mm
  • Other Device Same Type, Horizontal 0 mm
  • Other Device Same Type, Vertical 150 mm
Actuator Type: Rotary Handle
Contact Position Indication: ON / OFF / TRIP
Standards:
  • IEC/EN 60947-1
  • IEC/EN 60947-2
  • IEC/EN 60947-4-1
  • UL 60947-1
  • UL 60947-4-1
Remarks: UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
  • Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
  • Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA
  • Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
  • Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
  • Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
  • Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
  • Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
  • Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Horsepower Rating UL/CSA: (440 ... 480 V AC) Three Phase 0.75 Hp; (550 ... 600 V AC) Three Phase 0.75 Hp
Full Load Amps Motor Use:
  • (200 V AC) Three Phase 1.6 A
  • (208 V AC) Three Phase 1.6 A
  • (220 ... 240 V AC) Three Phase 1.6 A
  • (440 ... 480 V AC) Three Phase 1.6 A
Locked Rotor Amps:
  • (200 V AC) Three Phase 9.6 A
  • (208 V AC) Three Phase 9.6 A
  • (220 ... 240 V AC) Three Phase 9.6 A
  • (440 ... 480 V AC) Three Phase 9.6 A
  • (550 ... 600 V AC) Three Phase 9.6 A
General Use Rating UL/CSA: (600 V AC) 1.6 A
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-12 AWG; Stranded 1/2x 16-12 AWGTightening Torque UL/CSA: Main Circuit 10 ... 12 in·lb

Environmental

Ambient Air Temperature:
  • Around the Enclosure 0 ... +40 °C
  • Operation -25 ... +70 °C
  • Operation Compensated -25 ... +60 °C
  • Storage -50 ... +80 °C
Ambient Air Temperature Compensation: YesMaximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
 
Certificates and Declarations (Document Number)
ABS Certificate: 1SAA963001-0101
ATEX Certificate: 1SAA963000-3902
BV Certificate: 1SAA963001-0202
CB Certificate: 1SAA963002-2002
CQC Certificate: CQC2010010307387700CQC2019010307243864
Cut-off Current Characteristic: 1SAM300508F00011SAM300508F0003
Declaration of Conformity - CCC: 20209803070035262020980307003041
Declaration of Conformity - CE: 1SAD101100-3402
Declaration of Conformity - UKCA: 1SAD201100-3402
DNV GL Certificate: 1SAA963001-0304
EAC Certificate: 1SAA963000-2701
Environmental Information: 1SAC200049H0009
I²t Characteristic: 1SAM300507F00011SAM300507F0003
IECEx Certificate: 1SAA963000-4001
Instructions and Manuals: 2CDC131022M6802
Instructions and Manuals (Part 2): 2CDC131060M0202
KC Certificate: 1SAA963002-1502
LR Certificate: 1SAA963001-0502
REACH Declaration: 1SAA963005-4502
RINA Certificate: 1SAA963002-0802
RMRS Certificate: 1SAA918000-0704
RoHS Information: 1SAA963006-4502
Time-Current Characteristic Curve: 1SAM300505F0106
UL Certificate: E137861-20090225E345003-20090225

Classifications

Object Classification Code: F
ETIM 4: EC000074 - Motor protective circuit-breaker
ETIM 5: EC000074 - Motor protective circuit-breaker
ETIM 6: EC000074 - Motor protection circuit-breaker
ETIM 7: EC000074 - Motor protection circuit-breaker
ETIM 8: EC000074 - Motor protection circuit-breaker
eClass: V11.0 : 27370401
UNSPSC: 39121521
IDEA Granular Category Code (IGCC): 4731 >> Manual Starters
E-Number (Finland): 3705990
E-Number (Sweden): 3112122