ABB TF42-2.3 Thermal Overload Relay 1.7 ... 2.3 A

(No reviews yet) Write a Review
SKU:
TF42-2.3
Condition:
New
Availability:
In our warehouse: 3
$84.97

Description

The TF42-2.3 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.

General Information

Extended Product Type: TF42-2.3
Product ID: 1SAZ721201R1031
EAN: 4013614398070
Catalog Description: TF42-2.3 Thermal Overload Relay 1.7 ... 2.3 A

Popular Downloads

Data Sheet, Technical Information: 2CDC106023D0201
Instructions and Manuals: 2CDC106022M6802
Instructions and Manuals (Part 2): 1SAC200017M0002
Ex Operating Instructions: 2CDC106076M6801
Time-Current Characteristic Curve: 1SAZ700506F0011
CAD Dimensional Drawing: 2CDC001079B0201
Dimension Diagram: 1SAZ700405F0001

Dimensions

  • Product Net Width: 45 mm
  • Product Net Height: 88.3 mm
  • Product Net Depth / Length: 70.5 mm
  • Product Net Weight: 0.13 kg

Technical

Setting Range: 1.7 ... 2.3 A
Rated Operational Voltage:
  • Auxiliary Circuit 600 V AC/DC
  • Main Circuit 690 V AC
  • Main Circuit 600 V DC
Rated Operational Current (Ie): 2.3 A
Rated Frequency (f):
  • Auxiliary Circuit 50 Hz
  • Auxiliary Circuit 60 Hz
  • Auxiliary Circuit DC
  • Main Circuit 50 Hz
  • Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp): Auxiliary Circuit 6 kV; Main Circuit 6 kVRated Insulation Voltage (Ui): 690 V
Number of Poles: 3
Number of Auxiliary Contacts NC: 1
Number of Auxiliary Contacts NO: 1
Number of Protected Poles: 3
Conventional Free-air Thermal Current (Ith): Auxiliary Circuit NC 6 A; Auxiliary Circuit NO 4 A
Rated Operational Current AC-15 (Ie):
  • (120 V) NC 3 A
  • (120 V) NO 0.5 A
  • (240 V) NC 3 A
  • (240 V) NO 0.5 A
  • (400 V) NC 0.75 A
  • (400 V) NO 0.5 A
  • (500 V) NC 0.75 A
  • (500 V) NO 0.5 A
Rated Operational Current DC-13 (Ie):
  • (125 V) NC 0.55 A
  • (125 V) NO 0.55 A
  • (24 V) NC 1.25 A
  • (24 V) NO 1.25 A
  • (250 V) NC 0.27 A
  • (250 V) NO 0.27 A
  • (500 V) NC 0.15 A
  • (500 V) NO 0.15 A
  • (60 V) NC 0.55 A
  • (60 V) NO 0.55 A
Degree of Protection: IP20Pollution Degree: 3
Connecting Capacity Auxiliary Circuit:
  • Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
  • Flexible 1/2x 0.75 ... 1 mm²
  • Flexible 1/2x 1 ... 2.5 mm²
  • Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main Circuit:
  • Flexible with Ferrule 1/2x 0.75 ... 4 mm²
  • Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²
  • Flexible 1/2x 0.75 ... 4 mm²
  • Rigid 1/2x 0.75 ... 4 mm²
Tightening Torque: Auxiliary Circuit 1 ... 1.2 N·m; Main Circuit 1.5 ... 2.5 N·mWire Stripping Length: Auxiliary Circuit 9 mm; Main Circuit 12 mm
Recommended Screw Driver: Main Circuit Pozidriv 2
Power Loss: at Rated Operating Conditions per Pole 1.1 ... 2.0 W
Suitable For:
  • AF09
  • AF12
  • AF16
  • AF26
  • AF30
  • AF38
Standards:
  • IEC/EN 60947-1
  • IEC/EN 60947-4-1
  • IEC/EN 60947-5-1
  • UL 60947-1
  • UL 60947-4-1

Technical UL/CSA

Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
Contact Rating UL/CSA:
  • (NC:) B600
  • (NC:) Q600
  • (NO:) Q600
  • (NO:) D300
Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 18-10 AWG; Stranded 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA: Flexible 1/2x 18-12 AWG; Stranded 1/2x 18-12 AWG
Tightening Torque UL/CSA: Auxiliary Circuit 9 ... 11 in·lb; Main Circuit 13 ... 22 in·lb

Environmental

Ambient Air Temperature:
  • Operation -25 ... +60 °C
  • Operation Compensated -25 ... +60 °C
  • Storage -50 ... +80 °C
Ambient Air Temperature Compensation: Yes
Maximum Operating Altitude Permissible: 2000 m
Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations (Document Number)
ABS Certificate: 1SAA941001-0102
ATEX Certificate: 1SAA941001-3901
BV Certificate: 1SAA941001-0203
CB Certificate: 1SAA941009-2001
CQC Certificate: CQC2011010309464423
Declaration of Conformity - CCC: 2020980304001788
Declaration of Conformity - CE: 1SAD938513-0181
Declaration of Conformity - UKCA: 1SAD938501-1181
DNV GL Certificate: 1SAA941001-0302
EAC Certificate: 1SAA941002-2701
Environmental Information: 1SAC200057H0009
GL Certificate: 1SAA941007-0401
IECEx Certificate: 1SAA941003-4001
Instructions and Manuals: 2CDC106022M6802
Instructions and Manuals (Part 2): 1SAC200017M0002
LR Certificate: 1SAA941001-0502
REACH Declaration: 2CMT2021-006202
RINA Certificate: 1SAA941000-0802
RMRS Certificate: 1SAA941000-0704
RoHS Information: 2CMT2021-006277
Time-Current Characteristic Curve: 1SAZ700506F0011
UL Certificate: E48139-20090126

Classifications

Object Classification Code: F
ETIM 4: EC000106 - Thermal overload relay
ETIM 5: EC000106 - Thermal overload relay
ETIM 6: EC000106 - Thermal overload relay
ETIM 7: EC000106 - Thermal overload relay
ETIM 8: EC000106 - Thermal overload relay
eClass: V11.0 : 27371501
UNSPSC: 39122330
IDEA Granular Category Code (IGCC): 5366 >> Thermal overload relay

View AllClose