The Baumer FUF 100A2011 10229670 is a diffuse type fiber optic sensor with a smooth sensing head and a sensing distance of 115 mm. It features a cylindrical smooth fiber optic head made of aluminum, measuring 4 mm in width and 24 mm in length. The sensor operates within a temperature range of -25 to +250 °C and has an exit angle of 60°. It is compatible with infrared light at 1450 nm but does not allow for shortening of the fiber optics or adaptation of the lens. The fiber optic cable is 100 cm long, made of glass, and encased in a brass chromium-plated jacket with a diameter of 5 mm. The fixed bending radius is 15 mm, and the mobile bending radius is 30 mm.
- Particular characteristics:
- Smooth sensing head
- Operating principle:
- Diffuse type
- Sensing distance Tw:
- 115 mm
- Fiber optic head:
- Cylindrical smooth
- Operating temperature:
- -25 +250 °C
- Exit angle:
- 60°
- Fiber optics can be shortened to length:
- No
- Integrated lens:
- No
- Adaptable lens:
- No
- Infrared light compatibility (1450 nm):
- YesWidth / diameter (head)=4 mm
- Height / length (head):
- 24 mm
- Material (head):
- Aluminum
- Bending radius (fixed):
- 15 mm
- Bending radius (mobile):
- 30 mm
- Cable jacket diameter:
- 5 mm
- Material cable jacket:
- Brass chromium plated
- Fiber cross section:
- 2 mm²
- Material (fiber optic cable):
- Glass
- Length (fiber optic cable):
- 100 cm
- Datasheet:
- View