Baumer IR12.D06S-Q50.IA1Z.7BO 11141039 is a quasi-flush mounted inductive sensor with a measuring distance of 0 to 6 mm and a high resolution of less than 0.005 mm (static) and less than 0.01 mm (dynamic). It features repeat accuracy of 0.01 mm and linearity errors ranging from ±300 µm to ±720 µm. The sensor is designed to handle temperature drifts of ±4% to ±6% and has a rapid response time of less than 1 ms. Operating on a voltage supply range of 8 to 36 VDC and a maximum current consumption of 10 mA, it includes an analog output of 4 to 20 mA and supports load resistance specifications tailored to the voltage supply. It offers short circuit and reverse polarity protection, and is constructed with a brass nickel-plated housing and a PBT sensing face. The cylindrical threaded design measures 12 mm in diameter and 50 mm in length, with an M12 connector type. It can operate within temperatures of -25 to +75 °C, has a maximum tightening torque of 15 Nm, and is rated IP 67 for protection against dust and water ingress.
- Mounting type:
- Quasi-flush
- Measuring distance Sd:
- 0 6 mm
- Resolution:
- < 0.005 mm (stat.) < 0.01 mm (dynam.)
- Repeat accuracy:
- 0.01 mm
- Linearity error:
- ± 300 µm (S = 1,5 ... 4,5 mm) ± 720 µm (S = 0 ... 6 mm)
- Temperature drift:
- ± 4 % (Full Scale: 0 ... +60 °C) ± 6 % (Full Scale: -25 ... +75 °C)
- Response time (factory characteristic):
- < 1 ms
- Voltage supply range +Vs:
- 8 36 VDC
- Current consumption max. (no load):
- 10 mA
- Output circuit:
- Analog 4 ... 20 mA
- Load resistance:
- < 50 Ohm/V * Vs - 150 Ohm > 500 Ohm (Vs = 30 36 VDC)
- Short circuit protection:
- Yes
- Reverse polarity protection:
- Yes
- Design:
- Cylindrical threaded
- Material (sensing face):
- PBT
- Housing material:
- Brass nickel plated
- Dimension:
- 12 mm
- Housing length:
- 50 mm
- Connection types:
- Connector M12
- Tightening torque max.:
- 15 Nm (A: 10 Nm)
- Operating temperature:
- -25 +75 °C
- Protection class:
- IP 67
- Datasheet:
- View
- Operating Manual:
- View
- QN-QUOTE-REQUEST:
- true