Leuze KRT3CW.L3S2/2T-200-M12 Contrast sensor
Leuze
$244.00
KRT3CW.L3S2/2T-200-M12 Contrast sensor
- Series:
- 3C
- Special version:
- Teach input,Time function
- Operating range:
- 14.5 mm ± 2 mm
- Beam path:
- Focused
- Light source:
- LED, White
- Transmitted-signal shape:
- Pulsed
- LED group:
- Exempt group (in acc. with EN 62471)
- Light spot size [at sensor distance]:
- 1.5 mm x 4 mm [14.5 mm]
- Light spot orientation:
- Vertical
- Type of light spot geometry:
- Rectangular
- Light beam exit:
- Front
- Focus:
- Fixed
- Wavelength:
- 400 ... 750 nm
- Repeatability:
- 0.02 mm
- Protective circuit:
- Polarity reversal protection,Short circuit protected
- Supply voltage UB:
- 12 ... 30 V, DC, Incl. residual ripple
- Residual ripple:
- 0 ... 15 %, From UB
- Open-circuit current:
- 0 ... 25 mA
- Number of teach inputs:
- 1 Piece(s)
- Switching voltage:
- high: ?8V,low: ? 2 V or not connected
- Delay:
- 10 ms
- Input resistance:
- 15,000 ?
- Function:
- Keyboard lockout,Setting the pulse stretching,Teach-in
- Active switching state:
- High
- Teach process:
- Static 2-point
- Number of digital switching outputs:
- 1 Piece(s)
- Switching current, max.:
- 100 mA
- Switching voltage:
- high: ?(UB-2V),low: ? 2 V
- Switching element:
- Transistor, NPN
- Switching principle:
- Light switching
- Switching frequency:
- 10,000 Hz
- Response time:
- 0.05 ms
- Readiness delay:
- 300 ms
- Response jitter:
- 20 µs
- Function:
- Signal OUT,Teach input,Voltage supply
- Type of connection:
- Cable with connector
- Cable length:
- 200 mm
- Thread size:
- M12
- Type:
- Male
- Material:
- Metal
- No. of pins:
- 4 -pin
- Encoding:
- A-coded
- Design:
- Cubic
- Dimension (W x H x L):
- 11.4 mm x 34.2 mm x 18.3 mm
- Housing material:
- Plastic
- Plastic housing:
- PC-ABS
- Lens cover material:
- Plastic / PMMA
- Net weight:
- 20 g
- Housing color:
- Red
- Type of fastening:
- Via optional mounting device
- Compatibility of materials:
- ECOLAB
- Type of display:
- LED
- Number of LEDs:
- 2 Piece(s)
- Operational controls:
- Teach button
- Function of the operational control:
- Setting the pulse stretching,Switching-threshold adjustment,Teach-in
- Ambient temperature, operation:
- -40 ... 60 °C
- Ambient temperature, storage:
- -40 ... 70 °C
- Degree of protection:
- IP 67,IP 69K
- Protection class:
- III
- Approvals:
- c UL US
- Standards applied:
- EN IEC 60947-5-2
- Customs tariff number:
- 85365019
- ECLASS 5.1.4:
- 27270906
- ECLASS 8.0:
- 27270906
- ECLASS 9.0:
- 27270906
- ECLASS 10.0:
- 27270906
- ECLASS 11.0:
- 27270906
- ECLASS 12.0:
- 27270906
- ECLASS 13.0:
- 27270906
- ECLASS 14.0:
- 27270906
- ECLASS 15.0:
- 27270906
- ETIM 5.0:
- EC001820
- ETIM 6.0:
- EC001820
- ETIM 7.0:
- EC001820
- ETIM 8.0:
- EC001820
- ETIM 9.0:
- EC001820
- ETIM 10.0:
- EC001820
- Datasheet:
- View
- Declaration of Conformity:
- View