null

Leuze MSI-SR-2H21-01 Safety relay

Leuze
SKU:
MSI-SR-2H21-01
$265.82
Condition:
New
Current Stock:
MSI-SR-2H21-01 Safety relay
Series:
MSI-SR-2H21
Application:
Evaluation unit for two-hand control devices in accordance with DIN EN ISO 13851 type IIIC
Functions:
For stop category 0,Monitoring of the synchronous actuation,Two-channel actuation (one normally open contact and one normally closed contact for each)
Restart:
Through synchronous actuation
SIL:
3, IEC 61508
SILCL:
3, IEC/EN 62061
Performance Level (PL):
e, EN ISO 13849-1
PFHD:
3E-08 per hour
Mission time:
20 years, EN ISO 13849-1
Category:
4, EN ISO 13849-1
Continuous current per current path, max.:
6 A
Supply voltage UB:
24 V, AC/DC, -15 ... 10 %
Power consumption, max.:
1.9 W, For 24 V, plus output load
Nominal voltage UN:
24 V
Nominal frequency:
50 ... 60 Hz
Rated control supply voltage US at AC 60 Hz:
20.4 V
Rated control supply voltage US at AC 50 Hz:
26.4 V
Max. rated control supply voltage at AC 50 Hz:
26.4 V
Min. rated control supply voltage US at AC 50 Hz:
20.4 V
Min. rated control supply voltage US at DC:
20.4 V
Max. rated control supply voltage at DC:
26.4 V
Min. rated control supply voltage at DC:
20.4 V
Rated power DC:
2.4 W
Galvanic isolation between supply and control circuit:
Yes (when UN ? AC 115-230 V, AC 230 V)
Number of outputs, safety-oriented, non-delayed, contact-based:
2 Piece(s)
Number of outputs, safety-oriented, delayed, contact-based:
0 Piece(s)
Number of outputs, signaling function, non-delayed, contact-based:
1 Piece(s)
Release current paths:
NO
Signaling current paths:
NC
Contact material:
Ag alloy, gold-plated
Usage category AC-15 (NO contact):
Ue 230V, Ie 3A
Usage category DC-13 (NO contact):
Ue 24V, Ie 2,5A
Short circuit protection (NO contact):
gG class safety fuse 6A, melting integral
Nominal switching voltage, release current paths AC:
230 V
Max. thermal continuous current Ith, release current paths:
6 A
Max. thermal continuous current Ith, signaling current paths:
2 A
Max. total current I² of all current paths:
9 A²
Mechanical life time:
100,000,000 switching cycles
Executing the switching function of the inputs:
Changeover
Nominal output voltage DC:
24 V
Input current at the control inputs (safety circuit/reset circuit):
60 mA
Max. peak current at the control inputs (safety circuit/reset circuit):
1,000 mA
Max. cable resistance, per channel:
? (5 + (1.333 x UB / UN - 1) x 200) ?
Response time (automatic start tA2):
40 ms
Response time (manual start tA1):
40 ms
Release time tR:
50 ms
Synchronous time monitoring tS:
500 ms
Recovery time tW:
250 ms
Regression delay:
50 ms
Number of connections:
1 Piece(s)
Function:
Signal IN,Signal OUT,Voltage supply
Type of connection:
Terminal
Type of terminal:
Screw terminal
No. of pins:
16 -pin
Connection cross sections:
1 x 0.2 to 2.5 mm², wire,1 x 0.25 to 2.5 mm², wire with wire-end sleeve,2 x 0.2 to 1.0 mm², wire,2 x 0.25 to 1.0 mm², wire with wire-end sleeve
Dimension (W x H x L):
22.5 mm x 96.5 mm x 114 mm
Net weight:
200 g
Housing color:
Gray
Type of fastening:
Snap-on mounting
Ambient temperature, operation:
-25 ... 55 °C
Approvals:
TÜV Rheinland,c UL US
Customs tariff number:
85364900
ECLASS 5.1.4:
27371905
ECLASS 8.0:
27371821
ECLASS 9.0:
27371821
ECLASS 10.0:
27371821
ECLASS 11.0:
27371821
ECLASS 12.0:
27371821
ECLASS 13.0:
27371821
ECLASS 14.0:
27371821
ECLASS 15.0:
27371821
ETIM 5.0:
EC001452
ETIM 6.0:
EC001452
ETIM 7.0:
EC001452
ETIM 8.0:
EC001452
ETIM 9.0:
EC001452
ETIM 10.0:
EC001452
Datasheet:
View
Brochure:
View
Declaration of Conformity:
View