Description
Technical Data
Construction
Description
SUPERFLEX???? PLUS N PUR 300V
Number of conductors/cross-section
7G1.0
Jacket material
PUR
Jacket color
grey RAL 7001
Outer ??
8,2 mm
Outer ??
0,323 inch
Weight
11,2 kg/100 m
Weight
77,1 Lbs/Mft
Cu-Index
6,9 kg/100 m
Cu-Index
46 Lbs/Mft
Element 1
Element construction
7G1.0
Conductor
CU-wire bare
Conductor category
- IEC 60228, Class 6
- Superfinely stranded DIN VDE 0295
- class 6
Conductor marking
- black
- with white number print
- green/yellow
Conductor marking standard
DIN EN 50334
Conductor insulation
Special TPE
overall construction
Overall stranding
- conductors layered construction
- layer pitch optimised
- conductors twisted without mechanical stress
Overall wrapping
Fleece taping
Jacket characteristics
- Flame-retardant
- self-extinguishing
- Oil resistant
- grease-resistant
- petrol-resistant (alcohol-free)
- kerosene-resistant
- Silicone-free
- Halogen free
Technical data
Rated voltage U0/U
300/500 V
Rated voltage UL
300 V
Test voltage type
AC3000V
Temperature according to UL
80 ?????C
Temperature range moving
-25 ?????C ??????? +80 ?????C
Temperature range fixed
-40 ?????C ??????? +80 ?????C
Minimum bending radius moving
7.5?????D
Minimum bending radius fixed
4?????D
Travel distance
???????100 m
Element 1
Element construction
7G1.0
Insulation resistance at 20 ?????C
1000 M?????????km
Operating capacitance wire-wire
81 pF/m
Operating capacitance wire-shield
117 pF/m
Approvals/Standards
Approvals
cURus
UL style
AWM 20233
Conformity
- CE
- RoHS
- REACH
Burning behavior according to
- IEC 60332-1
- DIN EN 60332-1-2
- VDE 0482 322-1-2
- UL 1581 Part VW-1 Flame Test
- UL FT1
Oil resistant according to
Oil Res II
Halogen free according to
- DIN EN 60754-1
- IEC 60754-1
UV-resistant according to
DIN EN ISO 4892-2-A
General
Note
CE These products are in conformity with the EU Low Voltage Directive 2014/35/EU
Machine and device construction, transport and conveyor technology, HVAC technology In areas with high concentrations of people or material assets, where corrosive gases need to be avoided in the event of fire As a monitoring, measurement and control cable for industrial applications Especially for harsh environments For installation in energy chains with constant linear movement