Schneider Electric 8502SEO2V03 NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 240 VAC coil, open
Schneider Electric
$1,425.00
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 3 non-reversing contactor has a 90 ampere rating. Three phase NEMA Size 3 contactors have 25 HP at 200, 30 HP at 230 VAC and 50 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 7.09 inches tall, 5.47 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
- Local Signaling:
- no indicator
- Control Type:
- no control units
- Product Or Component Type:
- contactor
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Product Compatibility:
- circuit-breaker 150 A maximum, SCCR: 100 kA at 480 V AC || fuse J 200 A maximum, SCCR: 100 kA at 600 V AC || fuse T 200 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 200 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 200 A maximum, SCCR: 100 kA at
- Phase:
- 3 phase
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Product Certifications:
- UL listed file E78351 CCN NLDX || CSA
- Range Of Product:
- 8502S
- Control Circuit:
- common control circuit
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Nema Size:
- 3
- [Ue] Rated Operational Voltage:
- 600 V AC
- Line Rated Current:
- 90 A
- Country of Origin:
- Mexico
- Auxiliary Contact Composition:
- without
- Contactor Application:
- non-reversing
- Warranty:
- 18 months
- [Uc] Control Circuit Voltage:
- 240 V AC 60 Hz || 220 V AC 50 Hz
- Rated Power In Hp:
- 25 HP 200 V AC || 30 HP 230 V AC || 50 HP 460 V AC || 50 HP 575 V AC
- Provided Equipment:
- fuse not supplied
- Nema Degree Of Protection:
- not rated (open device)
- Electrical Connection:
- screw clamp terminals
- Depth:
- 165.10 mm
- Eu Rohs Directive:
- Not compliant
- Poles Description:
- 3P