Schneider Electric ATS22C25S6 Electronic Soft Starter Control 220V Pow
Schneider Electric
$4,071.00
This Altistart 22 soft starter can feed 3-phase asynchronous motors in supply line connection. It has a rating of 250A, a rated power from 75kW to 160kW and a rated voltage from 230V to 500V AC. It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
- [Us] Rated Supply Voltage:
- 230...600 V - 15...10 %
- Power Range:
- 55-100 kW 200-240 V 3 phase || 110-220 kW 380-440 V 3 phase || 110-220 kW 480-500 V 3 phase
- Discrete Input Number:
- 3
- Product Destination:
- asynchronous motors
- Phase:
- 3 phase
- Physical Interface:
- RS485 multidrop
- Type Of Start:
- start with torque control (current limited to 3.5 In)
- Ptc Probe Input:
- 750 Ohm
- Transmission Rate:
- 4800, 9600 or 19200 bps
- Shock Resistance:
- 15 gn 11 ms EN/IEC 60068-2-27
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Pollution Degree:
- level 2 IEC 60664-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Type Of Cooling:
- forced convection
- Operating Position:
- vertical +/- 10 degree
- Device Connection:
- in the motor supply line
- Discrete Input Logic:
- positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
- Function Available:
- internal bypass
- Protection Type:
- phase failure line || thermal protection motor || thermal protection starter
- Discrete Output Number:
- 2
- Power Dissipation In W:
- 129 W for standard applications
- Discrete Output Type:
- relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Supply Voltage Limits:
- 195-660 V
- Communication Data Link:
- serial
- Net Weight:
- 33 kg
- Factory Setting Current:
- 240 A
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
- Warranty:
- 18 months
- Supply Frequency:
- 50...60 Hz - 10...10 %
- Motor Power Kw:
- 132 kW 400 V || 132 kW 440 V || 75 kW 230 V || 160 kW 500 V
- China Rohs Regulation:
- X
- Product Or Component Type:
- soft starter
- Motor Starter Type:
- soft starter
- Width:
- 206 mm
- Connector Type:
- 1 RJ45
- Ambient Air Temperature For Storage:
- -25-70 °C
- Range Of Product:
- Altistart 22
- Product Specific Application:
- pumps and fans
- Marking:
- CE
- Component Name:
- ATS22
- Product Certifications:
- UL || CCC || CSA || GOST || C-tick
- Height:
- 425 mm
- Depth:
- 299 mm
- Installed Device:
- 31
- Relative Humidity:
- 0-95 % without condensation or dripping water EN/IEC 60068-2-3
- Communication Port Protocol:
- Modbus
- Electromagnetic Compatibility:
- conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electr
- Noise Level:
- 56 dB
- Network Frequency:
- 45...66 Hz
- Output Current:
- 0.4...1 Icl adjustable
- Utilisation Category:
- AC-53A
- Discrete Input Type:
- LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
- Mercury Free:
- Yes
- Icl Starter Rating:
- 250 A connection in the motor supply line for standard applications
- Maximum Switching Current:
- 5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
- [Uc] Control Circuit Voltage:
- 230 V - 15...10 % 50/60 Hz
- Standards:
- EN/IEC 60947-4-2
- Vibration Resistance:
- 1 gn 13-200 Hz)EN/IEC 60068-2-6 || 1.5 mm 2-13 Hz)EN/IEC 60068-2-6
- Ip Degree Of Protection:
- IP00
- Control Circuit Consumption:
- 20 W
- Minimum Switching Current:
- 100 mA 12 V DC relay outputs)
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
- Assembly Style:
- with heat sink
- Discrete Input Voltage:
- 24 V <= 30 V
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Rohs Exemption Information:
- Yes
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View