Schneider Electric ATS22C59S6 Electronic Soft Starter Control 220V Pow
Schneider Electric
$7,293.00
This Altistart 22 soft starter can feed 3-phase asynchronous motors in supply line connection. It has a rating of 590A, a rated power from 160kW to 400kW and a rated voltage from 230V to 500V AC. It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
- Marking:
- CE
- Maximum Switching Current:
- 5 A 250 V AC resistive 1 relay outputs || 5 A 30 V DC resistive 1 relay outputs || 2 A 250 V AC inductive 0.4 20 ms relay outputs || 2 A 30 V DC inductive 7 ms relay outputs
- Function Available:
- internal bypass
- Product Or Component Type:
- soft starter
- Vibration Resistance:
- 1 gn 13-200 Hz)EN/IEC 60068-2-6 || 1.5 mm 2-13 Hz)EN/IEC 60068-2-6
- Width:
- 304 mm
- Connector Type:
- 1 RJ45
- [Us] Rated Supply Voltage:
- 230...600 V - 15...10 %
- Type Of Start:
- start with torque control (current limited to 3.5 In)
- Phase:
- 3 phase
- Factory Setting Current:
- 477 A
- Assembly Style:
- with heat sink
- Warranty:
- 18 months
- Type Of Cooling:
- forced convection
- Physical Interface:
- RS485 multidrop
- Discrete Output Number:
- 2
- Relative Humidity:
- 0-95 % without condensation or dripping water EN/IEC 60068-2-3
- Product Certifications:
- CCC || UL || CSA || GOST || C-tick
- Device Connection:
- in the motor supply line
- Control Circuit Consumption:
- 20 W
- Range Of Product:
- Altistart 22
- Discrete Input Number:
- 3
- Discrete Input Type:
- LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
- Standards:
- EN/IEC 60947-4-2
- Mercury Free:
- Yes
- Supply Frequency:
- 50...60 Hz - 10...10 %
- Rohs Exemption Information:
- Yes
- Net Weight:
- 50 kg
- Discrete Input Logic:
- positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA
- Depth:
- 339.7 mm
- Motor Power Kw:
- 160 kW 230 V || 315 kW 400 V || 355 kW 440 V || 400 kW 500 V
- Protection Type:
- phase failure line || thermal protection motor || thermal protection starter
- Power Dissipation In W:
- 251 W for standard applications
- Transmission Rate:
- 4800, 9600 or 19200 bps
- Power Range:
- 110-220 kW 200-240 V 3 phase || 250-500 kW 480-500 V 3 phase || 250-500 kW 380-440 V 3 phase
- Component Name:
- ATS22
- Height:
- 455 mm
- Discrete Input Voltage:
- 24 V <= 30 V
- Ip Degree Of Protection:
- IP00
- Minimum Switching Current:
- 100 mA 12 V DC relay outputs)
- China Rohs Regulation:
- X
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Product Specific Application:
- pumps and fans
- Product Destination:
- asynchronous motors
- Icl Starter Rating:
- 590 A connection in the motor supply line for standard applications
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Motor Starter Type:
- soft starter
- Output Current:
- 0.4...1 Icl adjustable
- Installed Device:
- 31
- Pollution Degree:
- level 2 IEC 60664-1
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-60 °C with current derating 2.2 % per °C)
- Network Frequency:
- 45...66 Hz
- Communication Port Protocol:
- Modbus
- Operating Position:
- vertical +/- 10 degree
- Ptc Probe Input:
- 750 Ohm
- [Uc] Control Circuit Voltage:
- 230 V - 15...10 % 50/60 Hz
- Discrete Output Type:
- relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O || relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Noise Level:
- 56 dB
- Shock Resistance:
- 15 gn 11 ms EN/IEC 60068-2-27
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m
- Communication Data Link:
- serial
- Utilisation Category:
- AC-53A
- Ambient Air Temperature For Storage:
- -25-70 °C
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Supply Voltage Limits:
- 195-660 V
- Electromagnetic Compatibility:
- conducted and radiated emissions level A IEC 60947-4-2 || damped oscillating waves level 3 IEC 61000-4-12 || electrostatic discharge level 3 IEC 61000-4-2 || immunity to electrical transients level 4 IEC 61000-4-4 || immunity to radiated radio-electr
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View