- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- With Safety Function Safe Speed Monitor (Ssm):
- FALSE
- Connector Type:
- 1 RJ45
- Linearity Error:
- +/- 0.3 % of maximum value analogue input
- Standards:
- UL 508C || UL 618000-5-1 || EN/IEC 61800-5-1 || EN/IEC 61800-3
- Discrete Input Number:
- 4
- Transmission Frame:
- RTU
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Base Load Current At High Overload:
- 7.5 A
- Transmission Rate:
- 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
- With Safety Function Safe Position (Sp):
- FALSE
- China Rohs Regulation:
- X
- Height:
- 142 mm
- Maximum Output Frequency:
- 4 kHz
- Method Of Access:
- server Modbus serial
- Data Format:
- 8 bits, configurable odd, even or no parity
- Acceleration And Deceleration Ramps:
- U || S || linear from 0 to 999.9 s
- Number Of Addresses:
- 1-247
- Supply Frequency:
- 50/60 Hz +/- 5 %
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- With Safety Function Safe Operating Stop (Sos):
- FALSE
- With Safety Function Safe Torque Off (Sto):
- FALSE
- With Sft Fct Safe Stop 2 (Ss2):
- FALSE
- Maximum Horse Power Rating:
- 2 hp
- Transient Overtorque:
- 150-170 % of nominal motor torque depending on drive rating and type of motor
- Mounting Mode:
- cabinet mount
- Power Dissipation In W:
- forced cooling 72.0 W
- Maximum Acceleration Under Vibrational Stress (During Operation):
- 10 m/s² at 13...200 Hz
- Environmental Class (During Operation):
- class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3
- Width:
- 105 mm
- Type Of Polarization:
- no impedance
- Prospective Line Isc:
- 1 kA
- Ambient Air Temperature For Operation:
- -10-50 °C without derating || 50-60 °C with current derating 2.2 % per °C
- Maximum Output Voltage:
- 240 V
- Maximum Acceleration Under Shock Impact (During Operation):
- 150 m/s² at 11 ms
- Speed Range:
- 45311
- With Safety Function Safe Brake Management (Sbc/Sbt):
- FALSE
- Electromagnetic Compatibility:
- electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 || electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 || immunity to conducted disturbances level 3 EN/IEC 61000-4-6 || radiated radio-frequency electromagnetic field
- Product Certifications:
- NOM || CSA || C-tick || UL || GOST || RCM || KC
- 4 Quadrant Operation Possible:
- FALSE
- Nominal Switching Frequency:
- 4 kHz
- Tightening Torque:
- 1.2 N.m
- Electromagnetic Emission:
- radiated emissions environment 1 category C2 EN/IEC 61800-3 2...16 kHz shielded motor cable || conducted emissions with integrated EMC filter environment 1 category C1 EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m || conducted emiss
- Ambient Air Temperature For Storage:
- -25-70 °C
- Apparent Power:
- 3.6 kVA 240 V heavy duty)
- Protection Type:
- line supply overvoltage || line supply undervoltage || overcurrent between output phases and earth || overheating protection || short-circuit between motor phases || against input phase loss in three-phase || thermal motor protection via the drive by
- Communication Service:
- read holding registers (03) 29 words || write single register (06) 29 words || write multiple registers (16) 27 words || read/write multiple registers (23) 4/4 words || read device identification (43)
- Speed Drive Output Frequency:
- 0.5-400 Hz
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- With Safety Function Safely Limited Position (Slp):
- FALSE
- Discrete Output Number:
- 2
- Relative Symmetric Network Frequency Tolerance:
- 0.05
- Overvoltage Category:
- class III
- Regulation Loop:
- adjustable PID regulator
- Marking:
- CE
- Volume Of Cooling Air:
- 16 m3/h
- Analogue Output Number:
- 1
- [Us] Rated Supply Voltage:
- 200...240 V - 15...10 %
- Depth:
- 156.2 mm
- Product Specific Application:
- simple machine
- Ambient Air Transport Temperature:
- -25-70 °C
- Nominal Output Current:
- 7.5 A
- Motor Slip Compensation:
- adjustable || preset in factory
- Brake Chopper Integrated:
- FALSE
- Frequency Resolution:
- analog input converter A/D, 10 bits || display unit 0.1 Hz
- Emc Filter:
- integrated
- Relay Output Number:
- 1
- Asynchronous Motor Control Profile:
- sensorless flux vector control || quadratic voltage/frequency ratio || voltage/frequency ratio (V/f)
- Noise Level:
- 45 dB
- Maximum Deflection Under Vibratory Load (During Operation):
- 1.5 mm at 2...13 Hz
- Quantity Per Set:
- set of 1
- Switching Frequency:
- 2...16 kHz adjustable || 4...16 kHz with derating factor
- Ip Degree Of Protection:
- IP20
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Operating Position:
- vertical +/- 10 degree
- Maximum Transient Current:
- 11.2 A 60 s heavy duty) || 12.4 A 2 s heavy duty)
- Line Current:
- 17.8 A 100 V heavy duty) || 14.9 A 120 V heavy duty)
- Physical Interface:
- 2-wire RS 485
- Product Or Component Type:
- variable speed drive
- Braking To Standstill:
- by DC injection
- Pollution Degree:
- 2
- Rohs Exemption Information:
- Yes
- Insulation:
- electrical between power and control
- Vibration Resistance:
- 1 gn 13-200 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz) - drive unmounted on symmetrical DIN rail - EN/IEC 60068-2-6
- Communication Port Protocol:
- Modbus
- Assembly Style:
- with heat sink
- Network Frequency:
- 50-60 Hz
- Warranty:
- 18 months
- Analogue Input Number:
- 1
- Continuous Output Current:
- 7.5 A 4 kHz
- Motor Power Kw:
- 1.5 kW
- Net Weight:
- 1.4 kg
- Time Constant:
- 20 ms +/- 1 ms for reference change
- With Safety Function Safe Direction (Sdi):
- FALSE
- With Safety Function Safe Stop 1 (Ss1):
- FALSE
- Mercury Free:
- Yes
- With Safety Function Safe Programmable Logic:
- FALSE
- With Safety Function Safely Limited Speed (Sls):
- FALSE
- Sampling Duration:
- 20 ms +/- 1 ms logic input || 10 ms analogue input
- Shock Resistance:
- 15 gn 11 ms EN/IEC 60068-2-27
- Range Of Product:
- Altivar 12
- Operating Altitude:
- > 3280.84...6561.68 ft (> 1000...2000 m) with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating