Schneider Electric ATV12HU40M3 Atv12 4Kw 240V 3Ph Heat Sink Tb
Schneider Electric
$729.00
This Altivar 12 variable speed drive can feed 3-phase asynchronous motors in supply line connection. It works at a rated power up to 4kW / 5hp and a rated voltage from 200V to 240V AC. It is designed with heatsink for normal environments and fan-cooled enclosure. Transient overtorque function prevents stoppages by unjamming the machine with extra torque, when needed, this reduces downtime and maintenance costs. It features underload and overload detection, this contribute to protect your installation. The Altivar 12 drive integrates as standard the Modbus communication protocol, which can be accessed via the RJ45 connector located on the underside of the drive. It is designed for simple industry and commercial machines and appliances, such as conveyors, pumps, extractors, access barriers and treadmills. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime. It features an optimized application of power and torque for ventilation and pumping applications, this allows up to 30% energy savings.
- Net Weight:
- 2 kg
- Height:
- 184 mm
- Discrete Input Number:
- 4
- Range Of Product:
- Altivar 12
- Assembly Style:
- with heat sink
- Maximum Horse Power Rating:
- 5 hp
- With Safety Function Safe Position (Sp):
- FALSE
- Asynchronous Motor Control Profile:
- quadratic voltage/frequency ratio || voltage/frequency ratio (V/f) || sensorless flux vector control
- Maximum Acceleration Under Shock Impact (During Operation):
- 150 m/s² at 11 ms
- Regulation Loop:
- adjustable PID regulator
- Acceleration And Deceleration Ramps:
- S || U || linear from 0 to 999.9 s
- Product Specific Application:
- simple machine
- Power Dissipation In W:
- forced cooling 128.0 W
- Electromagnetic Compatibility:
- electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || electrostatic discharge immunity test level 3 IEC 61000-4-2 || immunity to conducted disturbances level 3 IEC 61000-4-6 || radiated radio-frequency electromagnetic field immunity
- Brake Chopper Integrated:
- FALSE
- Vibration Resistance:
- 1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz) - drive unmounted on symmetrical DIN rail - IEC 60068-2-6
- With Safety Function Safe Stop 1 (Ss1):
- FALSE
- Physical Interface:
- 2-wire RS 485
- Environmental Class (During Operation):
- class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Data Format:
- 8 bits, configurable odd, even or no parity
- Depth:
- 141.2 mm
- Ambient Air Transport Temperature:
- -25-70 °C
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Mounting Mode:
- cabinet mount
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Switching Frequency:
- 2...16 kHz adjustable || 4...16 kHz with derating factor
- Noise Level:
- 50 dB
- Connector Type:
- 1 RJ45
- Tightening Torque:
- 1.2 N.m
- With Safety Function Safely Limited Speed (Sls):
- FALSE
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || > 3280.84...9842.52 ft (> 1000...3000 m) with current derating 1 % per 100 m
- Analogue Input Number:
- 1
- Transmission Rate:
- 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
- Pollution Degree:
- 2
- Marking:
- CE
- Base Load Current At High Overload:
- 16.7 A
- Overvoltage Category:
- class III
- Ip Degree Of Protection:
- IP20
- Product Certifications:
- NOM || CSA || C-tick || UL || GOST || RCM || KC
- Ambient Air Temperature For Operation:
- -10-50 °C without derating || 50-60 °C with current derating 2.2 % per °C
- Supply Frequency:
- 50/60 Hz +/- 5 %
- Maximum Output Voltage:
- 240 V
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Protection Type:
- line supply overvoltage || line supply undervoltage || overcurrent between output phases and earth || overheating protection || short-circuit between motor phases || against input phase loss in three-phase || thermal motor protection via the drive by
- Time Constant:
- 20 ms +/- 1 ms for reference change
- 4 Quadrant Operation Possible:
- FALSE
- Warranty:
- 18 months
- Continuous Output Current:
- 16.7 A 4 kHz
- Quantity Per Set:
- set of 1
- Nominal Switching Frequency:
- 4 kHz
- Insulation:
- electrical between power and control
- Ambient Air Temperature For Storage:
- -25-70 °C
- Maximum Acceleration Under Vibrational Stress (During Operation):
- 10 m/s² at 13...200 Hz
- Apparent Power:
- 8.3 kVA 240 V heavy duty)
- Frequency Resolution:
- analog input converter A/D, 10 bits || display unit 0.1 Hz
- Nominal Output Current:
- 16.7 A
- Motor Power Kw:
- 4 kW
- Maximum Output Frequency:
- 4 kHz
- With Safety Function Safe Programmable Logic:
- FALSE
- Operating Position:
- vertical +/- 10 degree
- Maximum Deflection Under Vibratory Load (During Operation):
- 1.5 mm at 2...13 Hz
- Transient Overtorque:
- 150-170 % of nominal motor torque depending on drive rating and type of motor
- Speed Drive Output Frequency:
- 0.5-400 Hz
- With Safety Function Safe Speed Monitor (Ssm):
- FALSE
- Sampling Duration:
- 20 ms +/- 1 ms logic input || 10 ms analogue input
- Number Of Addresses:
- 1-247
- Network Frequency:
- 50-60 Hz
- Method Of Access:
- server Modbus serial
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Product Or Component Type:
- variable speed drive
- With Safety Function Safe Torque Off (Sto):
- FALSE
- With Safety Function Safe Operating Stop (Sos):
- FALSE
- Standards:
- UL 508C || UL 618000-5-1 || IEC 61800-5-1 || IEC 61800-3
- Emc Filter:
- without EMC filter
- With Sft Fct Safe Stop 2 (Ss2):
- FALSE
- Width:
- 140 mm
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- Relative Symmetric Network Frequency Tolerance:
- 0.05
- Prospective Line Isc:
- 5 kA
- China Rohs Regulation:
- X
- Discrete Output Number:
- 2
- With Safety Function Safe Brake Management (Sbc/Sbt):
- FALSE
- Transmission Frame:
- RTU
- With Safety Function Safely Limited Position (Slp):
- FALSE
- Mercury Free:
- Yes
- Type Of Polarization:
- no impedance
- Motor Slip Compensation:
- preset in factory || adjustable
- Speed Range:
- 45311
- Analogue Output Number:
- 1
- Volume Of Cooling Air:
- 16.4 m3/h
- Communication Service:
- read holding registers (03) 29 words || write single register (06) 29 words || write multiple registers (16) 27 words || read/write multiple registers (23) 4/4 words || read device identification (43)
- Communication Port Protocol:
- Modbus
- Relay Output Number:
- 1
- Electromagnetic Emission:
- radiated emissions environment 1 category C2 IEC 61800-3 2...16 kHz shielded motor cable || conducted emissions IEC 61800-3
- [Us] Rated Supply Voltage:
- 200...240 V - 15...10 %
- Line Current:
- 23.8 A 100 V heavy duty) || 19.9 A 120 V heavy duty)
- Braking To Standstill:
- by DC injection
- Linearity Error:
- +/- 0.3 % of maximum value analogue input
- Maximum Transient Current:
- 25.0 A 60 s heavy duty) || 27.6 A 2 s heavy duty)
- Rohs Exemption Information:
- Yes
- With Safety Function Safe Direction (Sdi):
- FALSE
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View