Schneider Electric ATV212HD45N4 Atv212 45Kw 60Hp 460V Tri Ip20 Variable
Schneider Electric
$5,553.23
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 45kW / 60hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 38.1kg and its dimensions are, 240mm wide, 550mm high, 244mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
- Transmission Frame:
- RTU
- Response Time:
- FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Dielectric Strength:
- 3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
- Type Of Cable:
- without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
- China Rohs Regulation:
- X
- Asynchronous Motor Control Profile:
- voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio - Energy Saving, quadratic U/f || voltage/frequency ratio, 2 points || voltage/frequency ratio, 5 points || flux vector control without sensor, standar
- Mercury Free:
- Yes
- Minimum Switching Current:
- 3 mA 24 V DC configurable relay logic
- Acceleration And Deceleration Ramps:
- linear adjustable separately from 0.01 to 3200 s || automatic based on the load
- Noise Level:
- 64 dB 86/188/EEC
- Option Card:
- communication card LonWorks
- Torque Accuracy:
- +/- 15 %
- Product Specific Application:
- pumps and fans in HVAC
- Analogue Input Type:
- VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
- Product Certifications:
- UL || CSA || NOM 117 || C-tick
- Connector Type:
- 1 RJ45 || 1 open style
- Local Signalling:
- for DC bus energized 1 LED (red)
- [Us] Rated Supply Voltage:
- 380...480 V - 15...10 %
- Analogue Input Number:
- 2
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Discrete And Process Manufacturing:
- building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
- Transmission Rate:
- 9600 bps or 19200 bps
- Operating Position:
- vertical +/- 10 degree
- Phase:
- 3 phase
- Sampling Duration:
- 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
- Network Frequency:
- 47.5...63 Hz
- Electrical Connection:
- VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 50-50 mm² / AWG 1/0
- Accuracy:
- +/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
- Specific Application:
- HVAC
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Assembly Style:
- with heat sink
- Device Short Name:
- ATV212
- Width:
- 240 mm
- Maximum Transient Current:
- 103.4 A 60 s
- Regulation Loop:
- adjustable PI regulator
- Product Or Component Type:
- variable speed drive
- Speed Range:
- 45301
- Communication Port Protocol:
- Modbus || LonWorks || METASYS N2 || BACnet || APOGEE FLN
- Supply Voltage Limits:
- 323-528 V
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Tightening Torque:
- 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 24 N.m, 212 lb.in L1/R, L2/S, L3/T)
- Rohs Exemption Information:
- Yes
- Supply Frequency:
- 50...60 Hz - 5...5 %
- Speed Accuracy:
- +/- 10 % of nominal slip 0.2 Tn to Tn
- Motor Slip Compensation:
- adjustable || not available in voltage/frequency ratio motor control || automatic whatever the load
- Apparent Power:
- 61.9 kVA 380 V
- Relative Humidity:
- 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
- Discrete Input Type:
- F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
- Discrete Output Type:
- configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
- Isolation:
- electrical between power and control
- Type Of Polarization:
- no impedance
- Switching Frequency:
- 6...16 kHz adjustable || 8...16 kHz with derating factor
- Pollution Degree:
- 3 IEC 61800-5-1
- Depth:
- 244 mm
- Range Of Product:
- Altivar 212
- Vibration Resistance:
- 1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
- Continuous Output Current:
- 94 A 380 V || 94 A 460 V
- Ambient Air Temperature For Storage:
- -25-70 °C
- Circularity Profile:
- ENVEOLI110402EN
- Number Of Addresses:
- 1-247
- Environmental Characteristic:
- classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
- Insulation Resistance:
- >= 1 mOhm 500 V DC for 1 minute
- Data Format:
- 8 bits, 1 stop, odd even or no configurable parity
- Ip Degree Of Protection:
- IP21
- Communication Service:
- read device identification (43) || write multiple registers (16) 2 words maximum || time out setting from 0.1 to 100 s || read holding registers (03) 2 words maximum || monitoring inhibitable || write single register (06)
- Power Range:
- 30-50 kW 380-440 V 3 phase || 30-50 kW 480-500 V 3 phase
- Environmental Disclosure:
- ENVPEP110404EN
- Functionality:
- mid
- Output Voltage:
- <= power supply voltage
- Prospective Line Isc:
- 22 kA
- Maximum Horse Power Rating:
- 60 hp
- Power Dissipation In W:
- 1253 W
- Nominal Switching Frequency:
- 8 kHz
- Analogue Output Type:
- FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
- Motor Power Kw:
- 45 kW
- Protection Type:
- overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
- Physical Interface:
- 2-wire RS 485
- Motor Starter Type:
- variable speed drive
- Linearity Error:
- VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
- Discrete Input Logic:
- positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
- Warranty:
- 18 months
- Supply:
- internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
- Maximum Switching Current:
- 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
- Height:
- 550 mm
- Speed Drive Output Frequency:
- 0.5-200 Hz
- Transient Overtorque:
- 120-120 % of nominal motor torque +/- 10 % 60 s
- Discrete Output Number:
- 2
- Air Flow:
- 429 m3/h
- Product Destination:
- asynchronous motors
- Line Current:
- 83.8 A 380 V || 65.9 A 480 V
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Analogue Output Number:
- 1
- Ambient Air Temperature For Operation:
- -10-40 °C without derating) || 40-50 °C with derating factor)
- Frequency Resolution:
- display unit 0.1 Hz || analog input 0.024/50 Hz
- Sustainable Offer Status:
- Green Premium product
- Standards:
- IEC 61800-3 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 1 category C1 || EN 61800-3 category C3 || IEC 61800-3 environments 2 category C3 || EN 55011 class A group 1 || IEC 61800-5-1 || IEC 61800-3 environments 2 category C1
- Braking To Standstill:
- by DC injection
- Ip Degree Of Protection:
- IP20 on upper part without blanking plate on cover IEC 61800-5-1 || IP20 on upper part without blanking plate on cover IEC 60529 || IP21 IEC 61800-5-1 || IP21 IEC 60529 || IP41 on upper part IEC 61800-5-1 || IP41 on upper part IEC 60529
- Marking:
- CE
- Emc Filter:
- Class C2 EMC filter integrated
- Operating Altitude:
- 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View