Schneider Electric ATV212HU40N4 Atv212 4Kw 5Hp 480V Tri Cem Ip20

(No reviews yet) Write a Review
SKU:
ATV212HU40N4
UPC:
3606480322488
Condition:
New
Standards:
IEC 61800-3 environments 2 category C2 || IEC 61800-3 environments 1 category C1 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 2 category C3 || IEC 61800-3 category C3 || IEC 61800-3 category C2 || IEC 61800-3 || UL Type 1 ||
Rohs Exemption Information:
Yes
Accuracy:
+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Type Of Polarization:
no impedance
Number Of Addresses:
1-247
Functionality:
mid
Net Weight:
3.35 kg
Product Specific Application:
pumps and fans in HVAC
Physical Interface:
2-wire RS 485
Line Current:
6.4 A 480 V || 8.1 A 380 V
China Rohs Regulation:
X
Motor Power Kw:
4 kW
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Motor Starter Type:
variable speed drive
Power Range:
4-6 kW 380-440 V 3 phase || 4-6 kW 480-500 V 3 phase
Speed Drive Output Frequency:
0.5-200 Hz
Device Short Name:
ATV212
Speed Accuracy:
+/- 10 % of nominal slip 0.2 Tn to Tn
Local Signalling:
for DC bus energized 1 LED (red)
Isolation:
electrical between power and control
Maximum Horse Power Rating:
5 hp
Maximum Transient Current:
10 A 60 s
Depth:
150 mm
Connector Type:
1 open style || 1 RJ45
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Continuous Output Current:
9.1 A 380 V || 9.1 A 460 V
Type Of Cable:
without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Torque Accuracy:
+/- 15 %
Environmental Characteristic:
classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
Mercury Free:
Yes
Discrete Output Number:
2
Communication Port Protocol:
METASYS N2 || BACnet || APOGEE FLN || Modbus || LonWorks
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01 to 3200 s || automatic based on the load
Minimum Switching Current:
3 mA 24 V DC configurable relay logic
Air Flow:
60 m3/h
Communication Service:
write multiple registers (16) 2 words maximum || time out setting from 0.1 to 100 s || read device identification (43) || monitoring inhibitable || read holding registers (03) 2 words maximum || write single register (06)
Braking To Standstill:
by DC injection
Analogue Input Number:
2
Specific Application:
HVAC
Range Of Product:
Altivar 212
Apparent Power:
6.9 kVA 380 V
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-50 °C with derating factor)
Discrete And Process Manufacturing:
building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
Analogue Input Type:
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Relative Humidity:
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Option Card:
communication card LonWorks
Pollution Degree:
3 IEC 61800-5-1
Marking:
CE
Operating Position:
vertical +/- 10 degree
Width:
142 mm
Ip Degree Of Protection:
IP21
Network Frequency:
47.5...63 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Transient Overtorque:
120-120 % of nominal motor torque +/- 10 % 60 s
Switching Frequency:
6...16 kHz adjustable || 12...16 kHz with derating factor
Response Time:
FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Insulation Resistance:
>= 1 mOhm 500 V DC for 1 minute
Vibration Resistance:
1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Emc Filter:
Class C2 EMC filter integrated
Ambient Air Temperature For Storage:
-25-70 °C
Protection Type:
overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Sampling Duration:
2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Dielectric Strength:
3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
Supply Voltage Limits:
323-528 V
Height:
184 mm
Tightening Torque:
1.3 N.m, 11.5 lb.in L1/R, L2/S, L3/T) || 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Product Certifications:
CSA || NOM 117 || UL || C-tick
Prospective Line Isc:
5 kA
Ip Degree Of Protection:
IP20 on upper part without blanking plate on cover IEC 61800-5-1 || IP20 on upper part without blanking plate on cover IEC 60529 || IP21 IEC 61800-5-1 || IP21 IEC 60529 || IP41 on upper part IEC 61800-5-1 || IP41 on upper part IEC 60529
Noise Level:
51 dB 86/188/EEC
Assembly Style:
with heat sink
Linearity Error:
VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Analogue Output Type:
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Warranty:
18 months
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Supply Frequency:
50...60 Hz - 5...5 %
Product Destination:
asynchronous motors
Analogue Output Number:
1
Power Dissipation In W:
176 W
Phase:
3 phase
Output Voltage:
<= power supply voltage
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Asynchronous Motor Control Profile:
voltage/frequency ratio - Energy Saving, quadratic U/f || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio, 2 points || voltage/frequency ratio, 5 points || flux vector control without sensor, standar
Discrete Output Type:
configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Speed Range:
45301
Operating Altitude:
3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Data Format:
8 bits, 1 stop, odd even or no configurable parity
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Discrete Input Type:
F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Transmission Rate:
9600 bps or 19200 bps
Motor Slip Compensation:
automatic whatever the load || adjustable || not available in voltage/frequency ratio motor control
Electrical Connection:
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10
Regulation Loop:
adjustable PI regulator
Nominal Switching Frequency:
12 kHz
Frequency Resolution:
display unit 0.1 Hz || analog input 0.024/50 Hz
Product Or Component Type:
variable speed drive
Maximum Switching Current:
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Transmission Frame:
RTU
Discrete Input Logic:
positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric ATV212HU40N4 Atv212 4Kw 5Hp 480V Tri Cem Ip20
  • Schneider Electric ATV212HU40N4 Atv212 4Kw 5Hp 480V Tri Cem Ip20
$951.46

Description

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 4kW / 5hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 3.35kg and its dimensions are, 142mm wide, 184mm high, 150mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
View AllClose