Schneider Electric ATV212WD11N4 Atv212 11Kw 15Hp 480V Tri Cem Ip55

(No reviews yet) Write a Review
SKU:
ATV212WD11N4
UPC:
3606480322235
Condition:
New
Marking:
CE
Physical Interface:
2-wire RS 485
Sampling Duration:
2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Discrete Input Logic:
positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Accuracy:
+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Product Destination:
asynchronous motors
Standards:
IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 category C2 || IEC 61800-3 environments 2 category C1 || IEC 61800-3 category C3 || IEC 61800-5-1 || IEC 61800-3 environments 1 category C1 || IEC 61800-3
Tightening Torque:
0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 3 N.m, 26.5 lb.in L1/R, L2/S, L3/T)
Line Current:
16.9 A 480 V || 21.2 A 380 V
Transient Overtorque:
120-120 % of nominal motor torque +/- 10 % 60 s
Phase:
3 phase
Isolation:
electrical between power and control
Product Specific Application:
pumps and fans in HVAC
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Asynchronous Motor Control Profile:
voltage/frequency ratio, 5 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio - Energy Saving, quadratic U/f || flux vector control without sensor, standard || voltage/frequency ratio, 2 point
Maximum Transient Current:
24.8 A 60 s
Insulation Resistance:
>= 1 mOhm 500 V DC for 1 minute
Speed Accuracy:
+/- 10 % of nominal slip 0.2 Tn to Tn
Relative Humidity:
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Option Card:
communication card LonWorks
Network Frequency:
47.5...63 Hz
Regulation Loop:
adjustable PI regulator
Net Weight:
30.3 kg
Response Time:
FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Switching Frequency:
6...16 kHz adjustable || 12...16 kHz with derating factor
Rohs Exemption Information:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Discrete Output Type:
configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Product Or Component Type:
variable speed drive
Torque Accuracy:
+/- 15 %
Ambient Air Temperature For Operation:
-10-40 °C without derating) || 40-50 °C with derating factor)
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Circularity Profile:
ENVEOLI111252EN
Discrete Input Type:
F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Operating Position:
vertical +/- 10 degree
Local Signalling:
for DC bus energized 1 LED (red)
Operating Altitude:
3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Functionality:
mid
Noise Level:
57.4 dB 86/188/EEC
Output Voltage:
<= power supply voltage
Environmental Characteristic:
classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
Ip Degree Of Protection:
IP55
Supply Frequency:
50...60 Hz - 5...5 %
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Communication Service:
write multiple registers (16) 2 words maximum || read device identification (43) || time out setting from 0.1 to 100 s || write single register (06) || monitoring inhibitable || read holding registers (03) 2 words maximum
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Transmission Frame:
RTU
Number Of Addresses:
1-247
Vibration Resistance:
1.5 mm 3-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Data Format:
8 bits, 1 stop, odd even or no configurable parity
Type Of Polarization:
no impedance
Braking To Standstill:
by DC injection
Connector Type:
1 RJ45 || 1 open style
Dielectric Strength:
3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
Nominal Switching Frequency:
12 kHz
Type Of Cable:
without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Pollution Degree:
2 IEC 61800-5-1
Ip Degree Of Protection:
IP55 IEC 61800-5-1 || IP55 IEC 60529
Protection Type:
overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit
Specific Application:
HVAC
Warranty:
18 months
Frequency Resolution:
display unit 0.1 Hz || analog input 0.024/50 Hz
Environmental Disclosure:
ENVPEP111264EN
Motor Power Kw:
11 kW
Analogue Output Type:
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Maximum Horse Power Rating:
15 hp
Linearity Error:
VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Product Certifications:
C-tick || UL || NOM 117 || CSA
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01 to 3200 s || automatic based on the load
Supply Voltage Limits:
323-528 V
Emc Filter:
Class C2 EMC filter integrated
Width:
290 mm
Range Of Product:
Altivar 212
Transmission Rate:
9600 bps or 19200 bps
Height:
560 mm
Analogue Input Type:
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Discrete Output Number:
2
Motor Slip Compensation:
automatic whatever the load || adjustable || not available in voltage/frequency ratio motor control
Apparent Power:
17.1 kVA 380 V
Analogue Input Number:
2
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
China Rohs Regulation:
X
Speed Drive Output Frequency:
0.5-200 Hz
Communication Port Protocol:
BACnet || METASYS N2 || Modbus || LonWorks || APOGEE FLN
Mercury Free:
Yes
Minimum Switching Current:
3 mA 24 V DC configurable relay logic
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
315 mm
Maximum Switching Current:
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Ambient Air Temperature For Storage:
-25-70 °C
Analogue Output Number:
1
Continuous Output Current:
22.5 A 380 V || 22.5 A 460 V
Device Short Name:
ATV212
Speed Range:
45301
Prospective Line Isc:
22 kA
Electrical Connection:
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 16-16 mm² / AWG 4
Assembly Style:
with heat sink
$2,022.39

Description

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP55 and it has a built-in EMC filter. It works at a rated power up to 11kW / 15hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 30.3kg and its dimensions are, 290mm wide, 560mm high, 315mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
View AllClose