Schneider Electric ATV340U22N4 Atv340 2,2Kw 3Hp 400V Wo Ethernet Variab

(No reviews yet) Write a Review
SKU:
ATV340U22N4
UPC:
3606480966897
Condition:
New
Data Format:
8 bits, configurable odd, even or no parity
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Method Of Access:
slave Modbus RTU
Analogue Output Type:
software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits
Ambient Air Temperature For Storage:
-40-70 °C
With Safety Function Safe Programmable Logic:
FALSE
Pollution Degree:
2 IEC 61800-5-1
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Type Of Cooling:
forced convection
Range Of Product:
Altivar Machine ATV340
With Safety Function Safe Stop 1 (Ss1):
TRUE
With Safety Function Safe Direction (Sdi):
FALSE
Pollution Degree:
2
Product Or Component Type:
variable speed drive
Physical Interface:
2-wire RS 485
Regulation Loop:
adjustable PID regulator
Width:
85.0 mm
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Nominal Output Current:
5.6 A
Volume Of Cooling Air:
18.0 m3/h
Operating Altitude:
<= 9842.52 ft (3000 m) with current derating above 1000m
Option Card:
communication module, Profibus DP V1 || communication module, PROFINET || communication module, DeviceNet || communication module, CANopen || communication module, EtherCAT
Maximum Horse Power Rating:
3 hp normal duty || 3 hp heavy duty
Emc Filter:
class C3 EMC filter integrated
With Safety Function Safely Limited Position (Slp):
FALSE
Product Certifications:
UL || CSA || TÜV || EAC || CTick
Electrical Connection:
screw terminal 1.5...4 mm² line side || screw terminal 4...6 mm² DC bus || screw terminal 1.5...4 mm² motor || screw terminal 0.2...2.5 mm² control
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s || S, U or customized
Maximum Acceleration Under Shock Impact (During Operation):
70 m/s² at 22 ms
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Minimum Switching Current:
relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC
Operating Position:
vertical +/- 10 degree
Communication Port Protocol:
Modbus serial
Braking To Standstill:
by DC injection
Motor Slip Compensation:
can be suppressed || automatic whatever the load || not available in permanent magnet motor law || adjustable
Relay Output Number:
2
Relay Output Type:
relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles
Upgradeability:
Upgraded components available
Maximum Output Voltage:
480 V
Maximum Output Frequency:
0.599 kHz
Maximum Acceleration Under Vibrational Stress (During Operation):
5 m/s² at 9...200 Hz
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...9 Hz
Rohs Exemption Information:
Yes
Overvoltage Category:
class III
Type Of Polarization:
no impedance
With Safety Function Safe Torque Off (Sto):
TRUE
Ambient Air Temperature For Operation:
-15-50 °C without derating vertical position) || 50-60 °C with derating factor vertical position)
Noise Level:
55.4 dB
With Safety Function Safe Position (Sp):
FALSE
Discrete Input Number:
5
Analogue Input Type:
AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31
Product Specific Application:
machine
Transmission Frame:
RTU
Discrete Output Number:
2
Transmission Rate:
4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Supply Frequency:
50...60 Hz +/- 5 %
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Nominal Switching Frequency:
4 kHz
Line Current:
6.6 A 380 V normal duty) || 5.3 A 480 V normal duty) || 8.4 A 380 V heavy duty) || 6.6 A 480 V heavy duty)
With Safety Function Safe Operating Stop (Sos):
FALSE
Discrete Output Type:
programmable output DQ1, DQ2 30 V DC 100 mA
Ip Degree Of Protection:
IP20
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Marking:
CE
Net Weight:
1.8 kg
Continuous Output Current:
7.2 A 4 kHz normal duty || 5.6 A 4 kHz heavy duty
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Electrical Connection:
line side screw terminal 1.5...4 mm² AWG 14...AWG 12 || DC bus screw terminal 4...6 mm² AWG 12...AWG 10 || motor screw terminal 1.5...4 mm² AWG 14...AWG 12 || control screw terminal 0.2...2.5 mm² AWG 24...AWG 12
China Rohs Regulation:
X
Apparent Power:
5.2 kVA 480 V normal duty) || 5.5 kVA 480 V heavy duty)
Output Voltage:
<= power supply voltage
4 Quadrant Operation Possible:
TRUE
Brake Chopper Integrated:
TRUE
Depth:
232.5 mm
Asynchronous Motor Control Profile:
constant torque standard || optimized torque mode || variable torque standard
Maximum Switching Current:
relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R
Connector Type:
1 RJ45
Number Of Addresses:
1-247
Circularity Profile:
ENVEOLI1609005EN
Base Load Current At High Overload:
5.6 A
Maximum Transient Current:
7.9 A 60 s normal duty) || 9.7 A 2 s normal duty) || 10.1 A 2 s heavy duty) || 8 A 60 s heavy duty)
Analogue Input Number:
2
Mounting Mode:
cabinet mount
Height:
270.0 mm
Power Dissipation In W:
natural convection 65 W 380 V 4 kHz heavy duty) || forced convection 65 W 380 V 4 kHz heavy duty) || natural convection 80 W 380 V 4 kHz normal duty) || forced convection 80 W 380 V 4 kHz normal duty)
Ambient Air Transport Temperature:
-40-70 °C
Assembly Style:
with heat sink
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Discrete Input Logic:
16 preset speeds
Line Current:
8.4 A 380 V without line choke heavy duty) || 6.6 A 480 V without line choke heavy duty) || 6.6 A 380 V with external line choke normal duty) || 5.3 A 480 V with external line choke normal duty) || 5.1 A 380 V with external line choke heavy duty) ||
Discrete Input Type:
PTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable
Prospective Line Isc:
5 kA
Isolation:
between power and control terminals
Variant:
standard version
Standards:
IEC 61800-3 || IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C
Motor Power Kw:
3 kW normal duty || 2.2 kW heavy duty
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Phase:
3 phase
Base Load Current At Low Overload:
7.2 A
Synchronous Motor Control Profile:
reluctance motor || permanent magnet motor
With Safety Function Safely Limited Speed (Sls):
TRUE
Environmental Disclosure:
ENVPEP1609005EN
Analogue Output Number:
2
Protection Type:
thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent
$1,048.80

Description

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 2.2kW / 3hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. it weighs 1.8kg and its dimensions are, 85mm wide, 270mm high, 232.5mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM). It is eco-friendly and complies with directives such as RoHS relating to environmental protection.
View AllClose