Schneider Electric ATV630D75S6 Atv630Ip20 100Hp 600V Variable Speed Dr

(No reviews yet) Write a Review
SKU:
ATV630D75S6
UPC:
3606481324955
Condition:
New
Product Certifications:
TÜV || CSA || UL
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Relay Output Number:
3
Sustainable Offer Status:
Green Premium product
Emc Filter:
without EMC filter
Phase:
3 phase
Variant:
standard version
Quantity Per Set:
1
Range Of Product:
Altivar Process ATV600
Supply Frequency:
50...60 Hz - 5...5 %
Data Format:
8 bits, configurable odd, even or no parity
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Output Voltage:
<= power supply voltage
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Mounting Mode:
wall mount
Physical Interface:
Ethernet || 2-wire RS 485
Type Of Cooling:
forced convection
Maximum Output Frequency:
500 kHz
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Transmission Frame:
RTU
Depth:
297 mm
Method Of Access:
slave Modbus TCP
Continuous Output Current:
100 A 2.5 kHz normal duty || 83 A 2.5 kHz heavy duty
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Number Of Addresses:
1-247 Modbus serial
Product Or Component Type:
variable speed drive
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Ip Degree Of Protection:
IP20IEC 61800-5-1 || IP20IEC 60529
Upgradeability:
Upgraded components available
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
China Rohs Regulation:
X
Product Destination:
asynchronous motors || synchronous motors
Line Current:
89.4 A 600 V normal duty) || 70.1 A 600 V heavy duty)
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
[Us] Rated Supply Voltage:
600 V - 15...10 %
[Us] Rated Supply Voltage:
600 V
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Enclosure Mounting:
wall mounted
Analogue Output Number:
2
Volume Of Cooling Air:
406 m3/h
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Type Of Polarization:
no impedance
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Discrete Input Logic:
16 preset speeds
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Safety Function:
STO (safe torque off) SIL 3
Degree Of Protection:
UL type 1 UL 508C
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Device Short Name:
ATV630
Operating Position:
vertical +/- 10 degree
Isolation:
between power and control terminals
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Noise Level:
56 dB
Pollution Degree:
2 IEC 61800-5-1
Noise Level:
52 dB 86/188/EEC
Rohs Exemption Information:
Yes
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Ambient Air Temperature For Storage:
-40-70 °C
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Switching Frequency:
1...4.9 kHz adjustable || 2.5...4.9 kHz with derating factor
Marking:
CE
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Discrete Output Number:
0
Maximum Horse Power Rating:
100 hp 600 V normal duty || 75 hp 600 V heavy duty
Environmental Disclosure:
ENVPEP1706016EN
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Discrete Input Number:
8
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Width:
331 mm
Net Weight:
55 kg
Overvoltage Category:
III
Apparent Power:
92.9 kVA 600 V normal duty) || 72.9 kVA 600 V heavy duty)
Power Dissipation In W:
natural convection 287 W 600 V 2.5 kHz || forced convection 1206 W 600 V 2.5 kHz
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 50 mm² AWG 1 || line side screw terminal 50 mm² AWG 1
Circularity Profile:
ENVEOLI1706016EN
Analogue Input Number:
3
Prospective Line Isc:
70 kA
Communication Port Protocol:
Modbus serial || Modbus TCP || Ethernet
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Motor Slip Compensation:
automatic whatever the load || not available in permanent magnet motor law || adjustable || can be suppressed
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Nominal Switching Frequency:
2.5 kHz
Pollution Degree:
2
Speed Drive Output Frequency:
0.1-500 Hz
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Maximum Transient Current:
110 A 60 s normal duty) || 124.5 A 60 s heavy duty)
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Height:
822 mm
Product Specific Application:
process and utilities
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Regulation Loop:
adjustable PID regulator
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Mercury Free:
Yes
Braking To Standstill:
by DC injection
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Datasheet:
View
$13,450.78