Schneider Electric

Schneider Electric ATV630D75Y6 Atv630Ip00 75Kw 500V-690V Variable Spee

(No reviews yet) Write a Review
SKU:
ATV630D75Y6
UPC:
3606481325228
Condition:
New
Enclosure Mounting:
wall mounted
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Maximum Horse Power Rating:
75 hp 500 V normal duty || 60 hp 500 V heavy duty || 100 hp 690 V normal duty || 75 hp 690 V heavy duty
Product Certifications:
TÜV || UL || CSA
Discrete Output Number:
0
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Motor Power Kw:
55 kW 500 V normal duty) || 45 kW 500 V heavy duty) || 75 kW 690 V normal duty) || 55 kW 690 V heavy duty)
Number Of Addresses:
1-247 Modbus serial
Circularity Profile:
ENVEOLI1706016EN
Emc Filter:
integrated 25 m IEC 61800-3 category C3
Analogue Output Number:
2
Maximum Output Frequency:
500 kHz
[Us] Rated Supply Voltage:
500...690 V
Communication Port Protocol:
Ethernet || Modbus serial || Modbus TCP
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Standards:
UL 508C || IEC 61800-3 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Mounting Mode:
wall mount
Data Format:
8 bits, configurable odd, even or no parity
Relay Output Number:
3
Maximum Transient Current:
91.3 A 60 s normal duty) || 99 A 60 s heavy duty)
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Discrete Input Number:
8
Mercury Free:
Yes
Prospective Line Isc:
70 kA
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Range Of Product:
Altivar Process ATV600
Rohs Exemption Information:
Yes
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Isolation:
between power and control terminals
Depth:
297 mm
Transmission Frame:
RTU
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Safety Function:
STO (safe torque off) SIL 3
Method Of Access:
slave Modbus TCP
[Us] Rated Supply Voltage:
500...690 V - 15...10 %
Noise Level:
52 dB 86/188/EEC
Net Weight:
53 kg
Type Of Cooling:
forced convection
Motor Slip Compensation:
can be suppressed || adjustable || not available in permanent magnet motor law || automatic whatever the load
Product Destination:
asynchronous motors || synchronous motors
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 35...50 mm² AWG 2...AWG 1 || motor screw terminal 35...50 mm² AWG 2...AWG 1
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Variant:
standard version
Product Specific Application:
process and utilities
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Marking:
CE
Supply Frequency:
50...60 Hz - 5...5 %
Overvoltage Category:
III
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Nominal Switching Frequency:
2.5 kHz
Sustainable Offer Status:
Green Premium product
Analogue Input Number:
3
Product Or Component Type:
variable speed drive
Discrete Input Logic:
16 preset speeds
Operating Position:
vertical +/- 10 degree
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Switching Frequency:
1...4.9 kHz adjustable || 2.5...4.9 kHz with derating factor
Line Current:
82.7 A 500 V normal duty) || 87.7 A 690 V normal duty) || 71 A 500 V heavy duty) || 68.5 A 690 V heavy duty)
Quantity Per Set:
1
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Regulation Loop:
adjustable PID regulator
Ip Degree Of Protection:
IP00IEC 61800-5-1 || IP00IEC 60529 || IP20 with kit VW3A9706)IEC 61800-5-1 || IP20 with kit VW3A9706)IEC 60529
Power Dissipation In W:
natural convection 268 W 500 V 2.5 kHz || forced convection 1075 W 500 V 2.5 kHz
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Braking To Standstill:
by DC injection
Continuous Output Current:
83 A 2.5 kHz normal duty || 66 A 2.5 kHz heavy duty
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Device Short Name:
ATV630
Type Of Polarization:
no impedance
Asynchronous Motor Control Profile:
optimized torque mode || constant torque standard || variable torque standard
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Width:
331 mm
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Ambient Air Temperature For Storage:
-40-70 °C
Upgradeability:
Upgraded components available
Pollution Degree:
2
Phase:
3 phase
Height:
630 mm
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Physical Interface:
Ethernet || 2-wire RS 485
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Volume Of Cooling Air:
406 m3/h
Output Voltage:
<= power supply voltage
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Environmental Disclosure:
ENVPEP1706016EN
Pollution Degree:
2 IEC 61800-5-1
Speed Drive Output Frequency:
0.1-500 Hz
China Rohs Regulation:
X
Apparent Power:
104.8 kVA 690 V normal duty) || 81.9 kVA 690 V heavy duty)
Noise Level:
56 dB
Brochure:
View
Catalog:
View
Datasheet:
View
$14,457.23

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 25m cable conforming to category C3. It works at a rated supply voltage from 500V to 690VAC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 75kW/100HP (500V supply voltage) for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 55kW/75HP (500V supply voltage) for applications requiring significant overload (up to 150%). Its dimensions are 331mm (width) x 297mm (depth) x 630mm (height). It weighs 53kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by CE, CSA and TUV. It meets UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. Accessories (fan kit, graphic display terminal) and options (line chokes, dv/dt filter, sinus filter, EMC filter) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose