Schneider Electric ATV630D90Y6 Atv630Ip00 90Kw 500V-690V Variable Spee

(No reviews yet) Write a Review
SKU:
ATV630D90Y6
UPC:
3.60648E+12
Condition:
New
Line Current:
108.3 A 500 V normal duty) || 99.4 A 690 V normal duty) || 82.7 A 500 V heavy duty) || 87.7 A 690 V heavy duty)
Motor Power Kw:
75 kW 500 V normal duty) || 55 kW 500 V heavy duty) || 90 kW 690 V normal duty) || 75 kW 690 V heavy duty)
Braking To Standstill:
by DC injection
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Maximum Transient Current:
124.5 A 60 s heavy duty) || 118.8 A 60 s normal duty)
Net Weight:
53 kg
Type Of Polarization:
no impedance
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Mounting Mode:
wall mount
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 50 mm² AWG 1 || line side screw terminal 50 mm² AWG 1
Method Of Access:
slave Modbus TCP
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Switching Frequency:
1...4.9 kHz adjustable || 2.5...4.9 kHz with derating factor
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Power Dissipation In W:
natural convection 320 W 500 V 2.5 kHz || forced convection 1433 W 500 V 2.5 kHz
Number Of Addresses:
1-247 Modbus serial
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Pollution Degree:
2
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Storage:
-40-70 °C
[Us] Rated Supply Voltage:
500...690 V
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Pollution Degree:
2 IEC 61800-5-1
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Analogue Input Number:
3
Type Of Cooling:
forced convection
Product Destination:
asynchronous motors || synchronous motors
Depth:
297 mm
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
China Rohs Regulation:
X
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s || S, U or customized
Height:
630 mm
Product Or Component Type:
variable speed drive
Transmission Frame:
RTU
Maximum Horse Power Rating:
100 hp 500 V normal duty || 75 hp 500 V heavy duty || 125 hp 690 V normal duty || 100 hp 690 V heavy duty
Communication Port Protocol:
Modbus TCP || Modbus serial || Ethernet
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Ip Degree Of Protection:
IP00IEC 61800-5-1 || IP00IEC 60529 || IP20 with kit VW3A9706)IEC 61800-5-1 || IP20 with kit VW3A9706)IEC 60529
Regulation Loop:
adjustable PID regulator
Apparent Power:
118.8 kVA 690 V normal duty) || 104.8 kVA 690 V heavy duty)
Prospective Line Isc:
70 kA
[Us] Rated Supply Voltage:
500...690 V - 15...10 %
Noise Level:
52 dB 86/188/EEC
Enclosure Mounting:
wall mounted
Device Short Name:
ATV630
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Overvoltage Category:
III
Upgradeability:
Upgraded components available
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Speed Drive Output Frequency:
0.1-500 Hz
Output Voltage:
<= power supply voltage
Marking:
CE
Environmental Disclosure:
ENVPEP1706016EN
Product Specific Application:
process and utilities
Width:
331 mm
Relay Output Number:
3
Emc Filter:
integrated 25 m IEC 61800-3 category C3
Supply Frequency:
50...60 Hz - 5...5 %
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Range Of Product:
Altivar Process ATV600
Asynchronous Motor Control Profile:
variable torque standard || optimized torque mode || constant torque standard
Volume Of Cooling Air:
406 m3/h
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Quantity Per Set:
1
Data Format:
8 bits, configurable odd, even or no parity
Safety Function:
STO (safe torque off) SIL 3
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Discrete Output Number:
0
Noise Level:
56 dB
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Phase:
3 phase
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Circularity Profile:
ENVEOLI1706016EN
Continuous Output Current:
83 A 2.5 kHz heavy duty || 108 A 2.5 kHz normal duty
Operating Position:
vertical +/- 10 degree
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Maximum Output Frequency:
500 kHz
Discrete Input Number:
8
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Standards:
UL 508C || IEC 61800-3 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Isolation:
between power and control terminals
Discrete Input Logic:
16 preset speeds
Motor Slip Compensation:
automatic whatever the load || can be suppressed || not available in permanent magnet motor law || adjustable
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Nominal Switching Frequency:
2.5 kHz
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Physical Interface:
Ethernet || 2-wire RS 485
Analogue Output Number:
2
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Product Certifications:
CSA || TÜV || UL
Variant:
standard version
Brochure:
View
Catalog:
View
Datasheet:
View
$16,746.84

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 25m cable conforming to category C3. It works at a rated supply voltage from 500V to 690VAC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 90kW/125HP (500V supply voltage) for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 75kW/100HP (500V supply voltage) for applications requiring significant overload (up to 150%). Its dimensions are 331mm (width) x 297mm (depth) x 630mm (height). It weighs 53kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by CE, CSA and TUV. It meets UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. Accessories (fan kit, graphic display terminal) and options (line chokes, dv/dt filter, sinus filter, EMC filter) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose