Schneider Electric

Schneider Electric ATV630U22N4 Variable Speed Drive Ip21 2,2Kw 400V/480

(No reviews yet) Write a Review
SKU:
ATV630U22N4
UPC:
3606480758119
Condition:
New
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Type Of Cooling:
forced convection
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Type Of Polarization:
no impedance
Product Or Component Type:
variable speed drive
Emc Filter:
integrated 50 m EN/IEC 61800-3 category C2 || integrated 150 m EN/IEC 61800-3 category C3
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Maximum Output Frequency:
500 kHz
Apparent Power:
3.2 kVA 480 V normal duty) || 2.4 kVA 480 V heavy duty)
Overvoltage Category:
III
Product Destination:
asynchronous motors || synchronous motors
Degree Of Protection:
UL type 1 UL 508C
Environmental Disclosure:
ENVPEP1501005EN
Power Dissipation In W:
natural convection 30 W 380 V 4 kHz || forced convection 60 W 380 V 4 kHz
Noise Level:
54.5 dB 86/188/EEC
Input Compatibility:
DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Quantity Per Set:
1
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Output Voltage:
<= power supply voltage
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Asynchronous Motor Control Profile:
constant torque standard || optimized torque mode || variable torque standard
Pollution Degree:
2
Variant:
standard version
Prospective Line Isc:
50 kA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Communication Port Protocol:
Modbus TCP || Modbus serial || Ethernet
Speed Drive Output Frequency:
0.1-500 Hz
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Mercury Free:
Yes
Physical Interface:
Ethernet || 2-wire RS 485
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Analogue Input Number:
3
China Rohs Regulation:
X
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Maximum Thdi:
<48 % full load IEC 61000-3-12
Phase:
3 phase
Maximum Horse Power Rating:
3 hp normal duty || 2 hp heavy duty
Nominal Switching Frequency:
4 kHz
Net Weight:
4.5 kg
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Pollution Degree:
2 EN/IEC 61800-5-1
Motor Power Kw:
2.2 kW normal duty) || 1.5 kW heavy duty)
Discrete Input Logic:
16 preset speeds
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Depth:
203 mm
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Motor Slip Compensation:
automatic whatever the load || adjustable || not available in permanent magnet motor law || can be suppressed
Transmission Frame:
RTU
Volume Of Cooling Air:
38 m3/h
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Safety Function:
STO (safe torque off) SIL 3
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Product Specific Application:
process and utilities
Height:
350 mm
Range Of Product:
Altivar Process ATV600
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Rohs Exemption Information:
Yes
Discrete Input Number:
8
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Operating Position:
vertical +/- 10 degree
Noise Level:
54.5 dB
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Device Short Name:
ATV630
Mounting Mode:
wall mount
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Product Certifications:
ATEX INERIS || CSA || ATEX zone 2/22 || TÜV || UL || DNV-GL
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
[Us] Rated Supply Voltage:
380...480 V
Relay Output Number:
3
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Isolation:
between power and control terminals
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Line Current:
4.3 A 380 V normal duty) || 3.8 A 480 V normal duty) || 3.1 A 380 V heavy duty) || 2.9 A 480 V heavy duty)
Marking:
CE
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Upgradeability:
Upgraded components available
Circularity Profile:
ENVEOLI1501005EN
Enclosure Mounting:
wall mounted
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Discrete And Process Manufacturing:
building - HVAC compressor centrifugal || food and beverage processing other application || mining mineral and metal fan || mining mineral and metal pump || oil and gas fan || water and waste water other application || building - HVAC screw compresso
Number Of Addresses:
1-247 Modbus serial
Power Range:
2.2-3 kW 380-440 V 3 phase || 2.2-3 kW 480-500 V 3 phase
Ip Degree Of Protection:
IP21IEC 61800-5-1 || IP21IEC 60529
Sustainable Offer Status:
Green Premium product
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Data Format:
8 bits, configurable odd, even or no parity
Method Of Access:
slave Modbus TCP
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 2.5...6 mm² AWG 14...AWG 10 || line side screw terminal 2.5...6 mm² AWG 14...AWG 10
Ambient Air Temperature For Storage:
-40-70 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Analogue Output Number:
2
Width:
144 mm
Regulation Loop:
adjustable PID regulator
Supply Frequency:
50...60 Hz - 5...5 %
Continuous Output Current:
5.6 A 4 kHz normal duty || 4 A 4 kHz heavy duty
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Braking To Standstill:
by DC injection
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Standards:
UL 508C || EN/IEC 61800-3 || EN/IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Discrete Output Number:
0
Maximum Transient Current:
6 A 60 s heavy duty) || 6.2 A 60 s normal duty)
Switching Frequency:
2...12 kHz adjustable || 4...12 kHz with derating factor
Brochure:
View
Catalog:
View
Datasheet:
View
$2,063.86

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 2.2kW / 3hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 1.5kW / 2hp for applications requiring significant overload (up to 150%). It weighs 4.5kg and its dimensions are, 144mm wide, 350mm high, 203mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose