Schneider Electric ATV630U30Y6 Atv630Ip00 3Kw 500V-690V Variable Speed

(No reviews yet) Write a Review
SKU:
ATV630U30Y6
UPC:
3606481325105
Condition:
New
Upgradeability:
Upgraded components available
Relay Output Number:
3
Braking To Standstill:
by DC injection
Maximum Transient Current:
4.6 A 60 s normal duty) || 4.7 A 60 s heavy duty)
Apparent Power:
5.7 kVA 690 V normal duty) || 4.3 kVA 690 V heavy duty)
Pollution Degree:
2 IEC 61800-5-1
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 4...10 mm² AWG 12...AWG 8 || line side screw terminal 4...10 mm² AWG 12...AWG 8
Switching Frequency:
2...8 kHz adjustable || 4...8 kHz with derating factor
Operating Position:
vertical +/- 10 degree
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Device Short Name:
ATV630
Motor Slip Compensation:
can be suppressed || adjustable || automatic whatever the load || not available in permanent magnet motor law
Method Of Access:
slave Modbus TCP
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Motor Power Kw:
2.2 kW 500 V normal duty) || 1.5 kW 500 V heavy duty) || 3 kW 690 V normal duty) || 2.2 kW 690 V heavy duty)
Height:
420 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Overvoltage Category:
III
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Variant:
standard version
Type Of Polarization:
no impedance
Speed Drive Output Frequency:
0.1-500 Hz
Prospective Line Isc:
70 kA
Continuous Output Current:
4.2 A 4 kHz normal duty || 3.1 A 4 kHz heavy duty
Noise Level:
52 dB 86/188/EEC
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Output Voltage:
<= power supply voltage
Environmental Disclosure:
ENVPEP1704001EN
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Data Format:
8 bits, configurable odd, even or no parity
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
[Us] Rated Supply Voltage:
500...690 V - 15...10 %
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Ambient Air Temperature For Storage:
-40-70 °C
China Rohs Regulation:
X
Analogue Output Number:
2
Product Specific Application:
process and utilities
Type Of Cooling:
forced convection
Mounting Mode:
wall mount
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Standards:
UL 508C || IEC 61800-3 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Maximum Horse Power Rating:
3 hp 500 V normal duty || 2 hp 500 V heavy duty || 3 hp 690 V heavy duty
Circularity Profile:
ENVEOLI1704001EN
Pollution Degree:
2
Volume Of Cooling Air:
330 m3/h
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Quantity Per Set:
1
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Communication Port Protocol:
Modbus TCP || Ethernet || Modbus serial
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Mercury Free:
Yes
Net Weight:
22 kg
[Us] Rated Supply Voltage:
500...690 V
Discrete Input Logic:
16 preset speeds
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Emc Filter:
integrated 25 m IEC 61800-3 category C3
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Product Or Component Type:
variable speed drive
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Physical Interface:
Ethernet || 2-wire RS 485
Marking:
CE
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission Frame:
RTU
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Range Of Product:
Altivar Process ATV600
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s || S, U or customized
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Analogue Input Number:
3
Line Current:
4.7 A 500 V normal duty) || 4.8 A 690 V normal duty) || 3.4 A 500 V heavy duty) || 3.6 A 690 V heavy duty)
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Supply Frequency:
50...60 Hz - 5...5 %
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Number Of Addresses:
1-247 Modbus serial
Product Destination:
asynchronous motors || synchronous motors
Depth:
242 mm
Power Dissipation In W:
natural convection 75 W 500 V 4 kHz || forced convection 58 W 500 V 4 kHz
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation:
between power and control terminals
Rohs Exemption Information:
Yes
Safety Function:
STO (safe torque off) SIL 3
Maximum Thdi:
<48 % with external line choke IEC 61000-3-12
Ip Degree Of Protection:
IP00IEC 61800-5-1 || IP00IEC 60529 || IP20 with kit VW3A9705)IEC 61800-5-1 || IP20 with kit VW3A9705)IEC 60529
Discrete Input Number:
8
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Discrete Output Number:
0
Enclosure Mounting:
wall mounted
Product Certifications:
CSA || UL || TÜV
Maximum Output Frequency:
500 kHz
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Regulation Loop:
adjustable PID regulator
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Sustainable Offer Status:
Green Premium product
Width:
246 mm
Phase:
3 phase
Nominal Switching Frequency:
4 kHz
Noise Level:
58 dB
$2,506.64

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 25m cable conforming to category C3. It works at a rated supply voltage from 500V to 690VAC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 3kW/3HP (500V supply voltage) for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 2.2kW/3HP (500V supply voltage) for applications requiring significant overload (up to 150%). Its dimensions are 246mm (width) x 242mm (depth) x 420mm (height). It weighs 22kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by CE, CSA and TUV. It meets UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. Accessories (fan kit, graphic display terminal) and options (line chokes, dv/dt filter, sinus filter, EMC filter) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.