Schneider Electric

Schneider Electric ATV650D22N4EU Atv650 Ip55 Ultype12 22Kw 30Hp 400V/480V

(No reviews yet) Write a Review
SKU:
ATV650D22N4EU
UPC:
3606480906855
Condition:
New
Noise Level:
53.7 dB 86/188/EEC
China Rohs Regulation:
X
Emc Filter:
integrated 50 m IEC 61800-3 category C2 || integrated 150 m IEC 61800-3 category C3
Analogue Input Number:
3
Maximum Horse Power Rating:
25 hp heavy duty || 30 hp normal duty
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Discrete Input Number:
8
Line Current:
34.4 A 480 V normal duty) || 34.1 A 380 V heavy duty) || 29.9 A 480 V heavy duty) || 39.6 A 380 V normal duty)
Circularity Profile:
ENVEOLI1406001EN
Standards:
IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || IEC 61800-3
Environmental Disclosure:
ENVPEP1406001EN
Relay Output Number:
3
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3
Phase:
3 phase
Frequency Resolution:
analog input 0.012/50 Hz || display unit 0.1 Hz
Width:
264 mm
Pollution Degree:
2 IEC 61800-5-1
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Speed Drive Output Frequency:
0.1-500 Hz
Height:
678 mm
Switching Frequency:
4...12 kHz with derating factor || 2...12 kHz adjustable
Net Weight:
20.6 kg
Operating Altitude:
1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Degree Of Protection:
UL type 12 UL 508C
Method Of Access:
slave Modbus TCP
Relay Output Type:
configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles
Depth:
330 mm
Enclosure Mounting:
wall mounted
Data Format:
8 bits, configurable odd, even or no parity
Noise Level:
53.7 dB
Sampling Duration:
5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Prospective Line Isc:
50 kA
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Analogue Output Number:
2
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Marking:
CE
Mercury Free:
Yes
Quantity Per Set:
1
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Product Specific Application:
process and utilities
Overvoltage Category:
III
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Device Short Name:
ATV650
Electromagnetic Compatibility:
radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency
Nominal Switching Frequency:
4 kHz
Physical Interface:
Ethernet || 2-wire RS 485
Permissible Temporary Current Boost:
1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty)
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external suppl
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Maximum Output Frequency:
500 kHz
Motor Slip Compensation:
adjustable || automatic whatever the load || not available in permanent magnet motor law
Ambient Air Temperature For Storage:
-40-70 °C
Asynchronous Motor Control Profile:
optimized torque mode || variable torque standard
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Range Of Product:
Altivar Process ATV600
Operating Position:
vertical +/- 10 degree
Ambient Air Temperature For Operation:
40-50 °C with derating factor) || -15-40 °C without derating)
Braking To Standstill:
by DC injection
Transmission Frame:
RTU
Product Destination:
asynchronous motors || synchronous motors
Rohs Exemption Information:
Yes
Electrical Connection:
line side screw terminal 10...16 mm² || motor screw terminal 16 mm² || control removable screw terminals 0.5...1.5 mm²
Discrete Output Number:
0
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Isolation:
between power and control terminals
Safety Function:
STO (safe torque off) SIL 3
Apparent Power:
24.9 kVA 480 V heavy duty) || 28.6 kVA 480 V normal duty)
Input Compatibility:
DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2 || DI1...DI6 discrete input level 1 PLC IEC 61131-2
Accuracy:
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Number Of Addresses:
1-247 Modbus serial
Mounting Mode:
wall mount
Ip Degree Of Protection:
IP55IEC 60529 || IP55IEC 61800-5-1
Communication Port Protocol:
Ethernet || Modbus serial
Option Card:
slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Product Certifications:
UL || ATEX INERIS || CSA || TÜV || ATEX zone 2/22 || Bureau Veritas
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Linearity Error:
AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Continuous Output Current:
39.2 A 4 kHz heavy duty || 46.3 A 4 kHz normal duty
Synchronous Motor Control Profile:
synchronous reluctance motor || permanent magnet motor
Upgradeability:
Upgraded components available
Product Or Component Type:
variable speed drive
Supply Frequency:
50...60 Hz - 5...5 %
Pollution Degree:
3
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Maximum Transient Current:
58.8 A 60 s heavy duty) || 50.9 A 60 s normal duty)
Output Voltage:
<= power supply voltage
Vibration Resistance:
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6
Protection Type:
safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || m
Sustainable Offer Status:
Green Premium product
Regulation Loop:
adjustable PID regulator
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Local Signalling:
for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Connector Type:
RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Type Of Polarization:
no impedance
Type Of Cooling:
forced convection
Discrete Input Logic:
16 preset speeds
Motor Power Kw:
18.5 kW heavy duty) || 22 kW normal duty)
[Us] Rated Supply Voltage:
380...480 V
Variant:
with disconnect switch
Datasheet:
View
$6,285.53

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 50m and 150m cable conforming to categories C2 and C3. It works at a rated supply voltage from 380V to 480VAC and it is an IP55 UL type 12 rated product. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 22kW/30HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 18.5kW/25HP for applications requiring significant overload (up to 150%). Its dimensions are 264mm (width) x 330mm (depth) x 678mm (height). It weighs 20.6kg. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by ATEX INERIS, ATEX zone 2/22, CE, UL, CSA, BV and TUV. It meets EN/IEC 61800, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 standards. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose