Schneider Electric ATV650D22N4U Atv650 Ip55 Ul Type12 22Kw 30Hp 400V/480
SKU:
ATV650D22N4U
UPC:
3.60648E+12
MPN:
Condition:
New
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Height:
678 mm
Operating Altitude:
1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Circularity Profile:
ENVEOLI1406001EN
Maximum Output Frequency:
500 kHz
Overvoltage Category:
III
Safety Function:
STO (safe torque off) SIL 3
Protection Type:
safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || m
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Output Voltage:
<= power supply voltage
Product Or Component Type:
variable speed drive
Maximum Transient Current:
58.8 A 60 s heavy duty) || 50.9 A 60 s normal duty)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Width:
264 mm
Range Of Product:
Altivar Process ATV600
Quantity Per Set:
1
Number Of Addresses:
1-247 Modbus serial
Accuracy:
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
40-50 °C with derating factor) || -15-40 °C without derating)
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Product Specific Application:
process and utilities
Physical Interface:
Ethernet || 2-wire RS 485
Relay Output Number:
3
Supply Frequency:
50...60 Hz - 5...5 %
Vibration Resistance:
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6
Noise Level:
53.7 dB 86/188/EEC
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Marking:
CE
Discrete Input Logic:
16 preset speeds
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Analogue Input Number:
3
Option Card:
slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A
Local Signalling:
for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Prospective Line Isc:
50 kA
Continuous Output Current:
39.2 A 4 kHz heavy duty || 46.3 A 4 kHz normal duty
Braking To Standstill:
by DC injection
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Line Current:
34.4 A 480 V normal duty) || 34.1 A 380 V heavy duty) || 29.9 A 480 V heavy duty) || 39.6 A 380 V normal duty)
Device Short Name:
ATV650
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Permissible Temporary Current Boost:
1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty)
Net Weight:
20.6 kg
Mercury Free:
Yes
Ip Degree Of Protection:
IP55IEC 60529 || IP55IEC 61800-5-1
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || automatic whatever the load
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Maximum Horse Power Rating:
25 hp heavy duty || 30 hp normal duty
Upgradeability:
Upgraded components available
[Us] Rated Supply Voltage:
380...480 V
Discrete Input Number:
8
Analogue Output Number:
2
Pollution Degree:
3
Operating Position:
vertical +/- 10 degree
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Type Of Cooling:
forced convection
Type Of Polarization:
no impedance
Motor Power Kw:
18.5 kW heavy duty) || 22 kW normal duty)
Apparent Power:
24.9 kVA 480 V heavy duty) || 28.6 kVA 480 V normal duty)
Product Destination:
asynchronous motors || synchronous motors
Isolation:
between power and control terminals
Noise Level:
53.7 dB
Phase:
3 phase
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Communication Port Protocol:
Modbus TCP || Modbus serial || Ethernet
Enclosure Mounting:
wall mounted
Depth:
299 mm
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Sampling Duration:
5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Rohs Exemption Information:
Yes
Electromagnetic Compatibility:
radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency
relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3
Degree Of Protection:
UL type 12 UL 508C
Linearity Error:
AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Transmission Frame:
RTU
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Data Format:
8 bits, configurable odd, even or no parity
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external suppl
Switching Frequency:
4...12 kHz with derating factor || 2...12 kHz adjustable
Electrical Connection:
line side screw terminal 10...16 mm² || motor screw terminal 16 mm² || control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. This variable speed drive features an integrated EMC filter with 50m and 150m cable...