Schneider Electric ATV650U30N4U Atv650 Ip55 Ul Type12 3Kw 400V/480V Vari

(No reviews yet) Write a Review
SKU:
ATV650U30N4U
UPC:
3606480907036
Condition:
New
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external suppl
Synchronous Motor Control Profile:
synchronous reluctance motor || permanent magnet motor
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Vibration Resistance:
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6
Relay Output Type:
configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles
Emc Filter:
integrated 50 m EN/IEC 61800-3 category C2 || integrated 150 m EN/IEC 61800-3 category C3
Ambient Air Temperature For Storage:
-40-70 °C
Option Card:
slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Operating Position:
vertical +/- 10 degree
Circularity Profile:
ENVEOLI1508009EN
Marking:
CE
Environmental Disclosure:
ENVPEP1508009EN
Local Signalling:
for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Discrete Input Logic:
16 preset speeds
Linearity Error:
AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Braking To Standstill:
by DC injection
Frequency Resolution:
analog input 0.012/50 Hz || display unit 0.1 Hz
Height:
678 mm
Method Of Access:
slave Modbus TCP
Enclosure Mounting:
wall mounted
Analogue Output Number:
2
Ambient Air Temperature For Operation:
40-50 °C with derating factor) || -15-40 °C without derating)
Discrete Output Number:
0
Maximum Transient Current:
7.9 A 60 s normal duty) || 8.4 A 60 s heavy duty)
Physical Interface:
Ethernet || 2-wire RS 485
Electromagnetic Compatibility:
radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency
Output Voltage:
<= power supply voltage
Data Format:
8 bits, configurable odd, even or no parity
Line Current:
5.1 A 480 V normal duty) || 4.5 A 380 V heavy duty) || 4 A 480 V heavy duty) || 5.8 A 380 V normal duty)
Connector Type:
RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Type Of Polarization:
no impedance
Nominal Switching Frequency:
4 kHz
Continuous Output Current:
5.6 A 4 kHz heavy duty || 7.2 A 4 kHz normal duty
Phase:
3 phase
Safety Function:
STO (safe torque off) SIL 3
Degree Of Protection:
UL type 12 UL 508C
Switching Frequency:
4...12 kHz with derating factor || 2...12 kHz adjustable
Accuracy:
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Mercury Free:
Yes
Device Short Name:
ATV650
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Net Weight:
10.6 kg
Pollution Degree:
2 EN/IEC 61800-5-1
Rohs Exemption Information:
Yes
Depth:
272 mm
Analogue Input Number:
3
Prospective Line Isc:
50 kA
Transmission Frame:
RTU
Motor Slip Compensation:
not available in permanent magnet motor law || adjustable || automatic whatever the load
Speed Drive Output Frequency:
0.1-500 Hz
Product Certifications:
DNV-GL || CSA || ABS || TÜV || ATEX INERIS || UL
Communication Port Protocol:
Modbus serial || Modbus TCP || Ethernet
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Maximum Output Frequency:
500 kHz
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
China Rohs Regulation:
X
Input Compatibility:
DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2 || DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Sampling Duration:
5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Protection Type:
safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || m
Width:
264 mm
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Quantity Per Set:
1
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Maximum Thdi:
<48 % full load IEC 61000-3-12
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Ip Degree Of Protection:
IP55IEC 60529 || IP55IEC 61800-5-1
[Us] Rated Supply Voltage:
380...480 V
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Permissible Temporary Current Boost:
1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty)
Apparent Power:
3.3 kVA 480 V heavy duty) || 4.2 kVA 480 V normal duty)
Overvoltage Category:
III
Standards:
EN/IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 508C
Type Of Cooling:
forced convection
Supply Frequency:
50...60 Hz - 5...5 %
Product Destination:
asynchronous motors || synchronous motors
Relay Output Number:
3
Motor Power Kw:
2.2 kW heavy duty) || 3 kW normal duty)
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Electrical Connection:
line side screw terminal 4...6 mm² || motor screw terminal 4...6 mm² || control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Isolation:
between power and control terminals
Noise Level:
52 dB 86/188/EEC
Product Specific Application:
process and utilities
Pollution Degree:
3
Noise Level:
52 dB
Discrete Input Number:
8
Asynchronous Motor Control Profile:
constant torque standard || variable torque standard || optimized torque mode
Number Of Addresses:
1-247 Modbus serial
Variant:
standard version
Sustainable Offer Status:
Green Premium product
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Range Of Product:
Altivar Process ATV600
Mounting Mode:
wall mount
Regulation Loop:
adjustable PID regulator
Operating Altitude:
1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Maximum Horse Power Rating:
4 hp normal duty || 3 hp heavy duty
Upgradeability:
Upgraded components available
Product Or Component Type:
variable speed drive
Brochure:
View
Catalog:
View
Datasheet:
View
$3,657.05

Description

Variable speed drive, Altivar Process ATV600, ATV650, 3 kW, 380...480 V, IP55/UL type 12
View AllClose