Schneider Electric ATV650U75N4U Atv650 Ip55 Ul Type12 7,5Kw 10Hp 400V/48

(No reviews yet) Write a Review
SKU:
ATV650U75N4U
UPC:
3606480907098
Condition:
New
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Overvoltage Category:
III
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Device Short Name:
ATV650
Protection Type:
safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || m
Transmission Frame:
RTU
Motor Power Kw:
5.5 kW heavy duty) || 7.5 kW normal duty)
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Noise Level:
52 dB
Speed Drive Output Frequency:
0.1-500 Hz
Nominal Switching Frequency:
4 kHz
Output Voltage:
<= power supply voltage
Regulation Loop:
adjustable PID regulator
China Rohs Regulation:
X
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Standards:
EN/IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 508C || EN/IEC 61800-3
Number Of Addresses:
1-247 Modbus serial
Product Destination:
asynchronous motors || synchronous motors
Variant:
standard version
Quantity Per Set:
1
Noise Level:
52 dB 86/188/EEC
Net Weight:
13.7 kg
Phase:
3 phase
Supply:
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection || external suppl
Height:
678 mm
Frequency Resolution:
analog input 0.012/50 Hz || display unit 0.1 Hz
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Sustainable Offer Status:
Green Premium product
Safety Function:
STO (safe torque off) SIL 3
Depth:
299 mm
Product Certifications:
TÜV || UL || CSA || DNV-GL || Bureau Veritas || ABS || ATEX INERIS
Synchronous Motor Control Profile:
synchronous reluctance motor || permanent magnet motor
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Analogue Output Number:
2
Electromagnetic Compatibility:
radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency
Maximum Transient Current:
19.1 A 60 s heavy duty) || 18.2 A 60 s normal duty)
Circularity Profile:
ENVEOLI1508009EN
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Sampling Duration:
5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output || 2 ms +/- 0.5 ms DI1...DI4) - discrete input
Upgradeability:
Upgraded components available
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Motor Slip Compensation:
not available in permanent magnet motor law || automatic whatever the load || can be suppressed || adjustable
Type Of Cooling:
forced convection
Data Format:
8 bits, configurable odd, even or no parity
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Asynchronous Motor Control Profile:
constant torque standard || optimized torque mode || variable torque standard
Analogue Input Number:
3
Input Compatibility:
DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2 || DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2
Maximum Output Frequency:
500 kHz
Enclosure Mounting:
wall mounted
Local Signalling:
for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red) || for local diagnostic 3 LEDs
Communication Port Protocol:
Ethernet || Modbus serial || Modbus TCP
Discrete Output Number:
0
Linearity Error:
AO1, AO2 +/- 0.2 % analog output || AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
Switching Frequency:
4...12 kHz with derating factor || 2...12 kHz adjustable
Apparent Power:
7.6 kVA 480 V heavy duty) || 9.9 kVA 480 V normal duty)
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Discrete Input Number:
8
Discrete Input Logic:
16 preset speeds
Mounting Mode:
wall mount
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R1, R2, R3 resistive, cos phi = 1 3
Relay Output Type:
configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles || configurable relay logic R1 fault relay NO/NC 100000 cycles
Line Current:
11.9 A 480 V normal duty) || 10.5 A 380 V heavy duty) || 9.2 A 480 V heavy duty) || 13.8 A 380 V normal duty)
Width:
264 mm
Permissible Temporary Current Boost:
1.5 x In 60 s heavy duty) || 1.1 x In 60 s normal duty)
Option Card:
slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A
Ambient Air Temperature For Storage:
-40-70 °C
Accuracy:
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output || +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Prospective Line Isc:
50 kA
Operating Altitude:
1000...4800 m with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Connector Type:
RJ45 on the remote graphic terminal)Modbus serial || RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
Ip Degree Of Protection:
IP55IEC 60529 || IP55IEC 61800-5-1
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Pollution Degree:
2 EN/IEC 61800-5-1
Degree Of Protection:
UL type 12 UL 508C
Range Of Product:
Altivar Process ATV600
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Ambient Air Temperature For Operation:
40-50 °C with derating factor) || -15-40 °C without derating)
Isolation:
between power and control terminals
Relay Output Number:
3
Braking To Standstill:
by DC injection
Type Of Polarization:
no impedance
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
[Us] Rated Supply Voltage:
380...480 V
Pollution Degree:
3
Maximum Horse Power Rating:
7.5 hp heavy duty || 10 hp normal duty
Product Or Component Type:
variable speed drive
Environmental Disclosure:
ENVPEP1508009EN
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Rohs Exemption Information:
Yes
Marking:
CE
Physical Interface:
Ethernet || 2-wire RS 485
Product Specific Application:
process and utilities
Supply Frequency:
50...60 Hz - 5...5 %
Electrical Connection:
motor screw terminal 6...10 mm² || line side screw terminal 4...6 mm² || control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 6...10 mm² AWG 10...AWG 8 || line side screw terminal 4...6 mm² AWG 12...AWG10
Emc Filter:
integrated 50 m EN/IEC 61800-3 category C2 || integrated 150 m EN/IEC 61800-3 category C3
Continuous Output Current:
12.7 A 4 kHz heavy duty || 16.5 A 4 kHz normal duty
Method Of Access:
slave Modbus TCP
Operating Position:
vertical +/- 10 degree
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Vibration Resistance:
1 gn 13-200 Hz)IEC 60068-2-6 || 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Brochure:
View
Catalog:
View
Datasheet:
View
$4,937.10

Description

Variable speed drive, Altivar Process ATV600, ATV650, 7.5kW/10 hp, 380...480 V, IP55/UL type 12
View AllClose