Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Discrete Input Number:
10
Environmental Disclosure:
ENVPEP1707007EN
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Analogue Output Number:
2
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Discrete Input Logic:
16 preset speeds
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Method Of Access:
slave Modbus TCP
Rohs Exemption Information:
Yes
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Assembly Style:
enclosed
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Width:
171 mm
With Safety Function Safely Limited Position (Slp):
FALSE
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Device Application:
Industrial Application
With Safety Function Safe Torque Off (Sto):
TRUE
China Rohs Regulation:
X
Number Of Addresses:
1-247 Modbus serial
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
[Us] Rated Supply Voltage:
600 V - 15...10 %
With Safety Function Safe Position (Sp):
FALSE
Maximum Transient Current:
26.4 A 60 s normal duty) || 27 A 60 s heavy duty)
Brake Chopper Integrated:
TRUE
Ambient Air Transport Temperature:
-40-70 °C
Apparent Power:
20.4 kVA 600 V normal duty) || 15.9 kVA 600 V heavy duty)
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Degree Of Protection:
UL type 1
Product Destination:
asynchronous motors || synchronous motors
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Type Of Polarization:
no impedance
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s || S, U or customized
With Safety Function Safely Limited Speed (Sls):
TRUE
Maximum Output Frequency:
599 Hz
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Variant:
standard version || with braking chopper
Volume Of Cooling Air:
103 m3/h
Type Of Polarization:
no impedance Modbus serial
Quantity Per Set:
1
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
With Safety Function Safe Operating Stop (Sos):
FALSE
Network Frequency:
50-60 Hz
Circularity Profile:
ENVEOLI1707007EN
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Isolation:
between power and control terminals
Continuous Output Current:
22 A 4 kHz normal duty || 18 A 4 kHz heavy duty
Pollution Degree:
2
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Height:
409 mm
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Relative Symmetric Network Frequency Tolerance:
0.05
Mercury Free:
Yes
Relay Output Number:
3
Braking To Standstill:
by DC injection
With Safety Function Safe Programmable Logic:
FALSE
Communication Port Protocol:
Modbus TCP || Modbus serial || EtherNet/IP
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Product Or Component Type:
variable speed drive
Phase:
3 phase
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
With Safety Function Safe Direction (Sdi):
FALSE
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Discrete Output Number:
2
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Base Load Current At High Overload:
18.0 A
Operating Position:
vertical +/- 10 degree
Base Load Current At Low Overload:
22.0 A
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
With Safety Function Safe Stop 1 (Ss1):
TRUE
Maximum Output Voltage:
600.0 V
Mounting Mode:
wall mount
Range Of Product:
Altivar Process ATV900
Noise Level:
56 dB
Product Specific Application:
process for industrial
Prospective Line Isc:
70 kA
Depth:
236 mm
Transmission Frame:
RTU
Number Of Addresses:
1-247
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Net Weight:
5.5 kg
Overvoltage Category:
III
4 Quadrant Operation Possible:
TRUE
Noise Level:
56 dB 86/188/EEC
Regulation Loop:
adjustable PID regulator
Power Dissipation In W:
forced convection 192 W 600 V 4 kHz || natural convection 136 W 600 V 4 kHz
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Analogue Input Number:
3
Nominal Switching Frequency:
4 kHz
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Emc Filter:
integrated || with EMC plate option
Upgradeability:
Upgraded components available
Data Format:
8 bits, configurable odd, even or no parity
Ambient Air Temperature For Storage:
-40-70 °C
Product Certifications:
CSA || UL || TÜV
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Asynchronous Motor Control Profile:
optimized torque mode || constant torque standard || variable torque standard
Motor Slip Compensation:
can be suppressed || adjustable || not available in permanent magnet motor law || automatic whatever the load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 6...10 mm² AWG 10...AWG 8 || line side screw terminal 6 mm² AWG 10 || DC bus screw terminal 6 mm² AWG 10
Sustainable Offer Status:
Green Premium product
Local Signalling:
local diagnostic 3 LED mono/dual colour) || presence of voltage 1 LED red) || embedded communication status 3 LED dual colour) || communication module status 4 LED dual colour)
Connector Type:
2 RJ45 || 1 RJ45
Ip Degree Of Protection:
IP21
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Physical Interface:
Ethernet || 2-wire RS 485
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Datasheet:
View
$5,004.54