Schneider Electric ATV930D22S6 Atv930Ip20 30Hp 600V Variable Speed Dri

(No reviews yet) Write a Review
SKU:
ATV930D22S6
UPC:
3606481325037
Condition:
New
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Assembly Style:
enclosed
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Degree Of Protection:
UL type 1
Marking:
CE
Height:
567 mm
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Product Certifications:
CSA || UL || TÜV
Number Of Addresses:
1-247 Modbus serial
Base Load Current At Low Overload:
34.0 A
Continuous Output Current:
34 A 4 kHz normal duty || 27 A 4 kHz heavy duty
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
With Safety Function Safe Direction (Sdi):
FALSE
Data Format:
8 bits, configurable odd, even or no parity
Analogue Input Number:
3
With Safety Function Safely Limited Position (Slp):
FALSE
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Physical Interface:
Ethernet || 2-wire RS 485
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Discrete Input Number:
10
Discrete Input Logic:
16 preset speeds
Local Signalling:
local diagnostic 3 LED mono/dual colour) || presence of voltage 1 LED red) || embedded communication status 3 LED dual colour) || communication module status 4 LED dual colour)
Apparent Power:
28 kVA 600 V normal duty) || 24.1 kVA 600 V heavy duty)
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Network Frequency:
50-60 Hz
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Pollution Degree:
2
Isolation:
between power and control terminals
Mounting Mode:
wall mount
Relative Symmetric Network Frequency Tolerance:
0.05
Brake Chopper Integrated:
TRUE
Product Or Component Type:
variable speed drive
Maximum Output Frequency:
599 Hz
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Maximum Output Voltage:
600.0 V
Maximum Transient Current:
40.8 A 60 s normal duty) || 40.5 A 60 s heavy duty)
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
[Us] Rated Supply Voltage:
600 V - 15...10 %
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Overvoltage Category:
III
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Noise Level:
58 dB 86/188/EEC
Volume Of Cooling Air:
330 m3/h
Depth:
242 mm
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Phase:
3 phase
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Sustainable Offer Status:
Green Premium product
Type Of Polarization:
no impedance
Net Weight:
23 kg
Number Of Addresses:
1-247
Environmental Disclosure:
ENVPEP1704001EN
Device Application:
Industrial Application
Variant:
with braking chopper || standard version
Connector Type:
2 RJ45 || 1 RJ45
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Mercury Free:
Yes
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Power Dissipation In W:
forced convection 495 W 600 V 4 kHz || natural convection 143 W 600 V 4 kHz
Nominal Switching Frequency:
4 kHz
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Prospective Line Isc:
70 kA
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Operating Position:
vertical +/- 10 degree
Ambient Air Temperature For Storage:
-40-70 °C
Discrete Output Number:
2
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
With Safety Function Safe Position (Sp):
FALSE
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 10 mm² AWG 8 || line side screw terminal 10 mm² AWG 8 || DC bus screw terminal 10 mm² AWG 8
With Safety Function Safely Limited Speed (Sls):
TRUE
Product Destination:
synchronous motors || asynchronous motors
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
With Safety Function Safe Torque Off (Sto):
TRUE
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Quantity Per Set:
1
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Ip Degree Of Protection:
IP20
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Type Of Polarization:
no impedance Modbus serial
Regulation Loop:
adjustable PID regulator
Width:
246 mm
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Noise Level:
58 dB
Base Load Current At High Overload:
27.0 A
Analogue Output Number:
2
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
With Safety Function Safe Stop 1 (Ss1):
TRUE
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
4 Quadrant Operation Possible:
TRUE
Communication Port Protocol:
Modbus TCP || EtherNet/IP || Modbus serial
Emc Filter:
integrated || with EMC plate option
With Safety Function Safe Operating Stop (Sos):
FALSE
Method Of Access:
slave Modbus TCP
With Safety Function Safe Programmable Logic:
FALSE
Upgradeability:
Upgraded components available
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Range Of Product:
Altivar Process ATV900
Transmission Frame:
RTU
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Motor Slip Compensation:
can be suppressed || automatic whatever the load || not available in permanent magnet motor law || adjustable
Ambient Air Transport Temperature:
-40-70 °C
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Rohs Exemption Information:
Yes
Braking To Standstill:
by DC injection
Circularity Profile:
ENVEOLI1704001EN
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
China Rohs Regulation:
X
Relay Output Number:
3
Switching Frequency:
2...8 kHz adjustable || 4...8 kHz with derating factor
Product Specific Application:
process for industrial
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Datasheet:
View
$6,921.29