Schneider Electric ATV930D55N4ZU variable speed drive, Altivar Process ATV900, ATV930, 75hp, 380 to 480V, cabinet Integration, IP20, for US
Schneider Electric
$7,654.08
variable speed drive, Altivar Process ATV900, ATV930, 75hp, 380 to 480V, cabinet Integration, IP20, for US
- Width:
- 265 mm
- Emc Filter:
- integrated || with EMC plate option
- China Rohs Regulation:
- X
- Environmental Disclosure:
- ENVPEP2007013EN
- Maximum Acceleration Under Shock Impact (During Operation):
- 150 m/s² at 11 ms
- 4 Quadrant Operation Possible:
- TRUE
- Type Of Polarization:
- no impedance
- Base Load Current At Low Overload:
- 106.0 A
- Ip Degree Of Protection:
- IP21
- Accuracy:
- +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60°C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60°C analog output
- Switching Frequency:
- 1...8 kHz adjustable || 2.5...8 kHz with derating factor
- Power Dissipation In W:
- natural convection 131 W 380 V 2.5 kHz || forced convection 917 W 380 V 2.5 kHz
- Phase:
- 3 phase
- Assembly Style:
- with heat sink
- With Safety Function Safely Limited Position (Slp):
- FALSE
- Standards:
- UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
- Sustainable Offer Status:
- Green Premium product
- Mounting Mode:
- cabinet mount
- Nominal Switching Frequency:
- 2.5 kHz
- Analogue Input Type:
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
- Electromagnetic Compatibility:
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50µs - 8/20µs surge immuni
- Discrete Output Type:
- logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
- Product Certifications:
- CSA || UL || TÜV
- Relay Output Type:
- configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
- Insulation Resistance:
- > 1 MOhm 500 V DC for 1 minute to earth
- Operating Altitude:
- <= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
- Weight:
- 53.6 kg
- Discrete Input Type:
- DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
- Net Weight:
- 53.6 kg
- With Safety Function Safe Brake Management (Sbc/Sbt):
- TRUE
- Product Or Component Type:
- variable speed drive
- With Safety Function Safe Speed Monitor (Ssm):
- FALSE
- Data Format:
- 8 bits, configurable odd, even or no parity Modbus serial
- Ambient Air Temperature For Storage:
- -40-70°C
- Shock Resistance:
- 15 gn 11 ms IEC 60068-2-27
- Range Of Product:
- Altivar Process ATV900
- With Safety Function Safe Operating Stop (Sos):
- FALSE
- Motor Power Kw:
- 55.0 kW normal duty || 45.0 kW heavy duty
- Relative Symmetric Network Frequency Tolerance:
- 0.05
- Upgradeability:
- Upgraded components available
- With Safety Function Safe Direction (Sdi):
- FALSE
- Exchange Mode:
- half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
- Vibration Resistance:
- 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
- Communication Port Protocol:
- EtherNet/IP || Modbus TCP || Modbus serial
- Braking To Standstill:
- by DC injection
- Product Specific Application:
- process for industrial
- Noise Level:
- 68.3 dB 86/188/EEC
- Base Load Current At High Overload:
- 88.0 A