Schneider Electric

Schneider Electric ATV930D55N4ZU variable speed drive, Altivar Process ATV900, ATV930, 75hp, 380 to 480V, cabinet Integration, IP20, for US

(No reviews yet) Write a Review
SKU:
ATV930D55N4ZU
MPN:
ATV930D55N4ZU
Condition:
New
Width:
265 mm
Emc Filter:
integrated || with EMC plate option
China Rohs Regulation:
X
Environmental Disclosure:
ENVPEP2007013EN
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
4 Quadrant Operation Possible:
TRUE
Type Of Polarization:
no impedance
Base Load Current At Low Overload:
106.0 A
Ip Degree Of Protection:
IP21
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60°C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60°C analog output
Switching Frequency:
1...8 kHz adjustable || 2.5...8 kHz with derating factor
Power Dissipation In W:
natural convection 131 W 380 V 2.5 kHz || forced convection 917 W 380 V 2.5 kHz
Phase:
3 phase
Assembly Style:
with heat sink
With Safety Function Safely Limited Position (Slp):
FALSE
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Sustainable Offer Status:
Green Premium product
Mounting Mode:
cabinet mount
Nominal Switching Frequency:
2.5 kHz
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50µs - 8/20µs surge immuni
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Product Certifications:
CSA || UL || TÃœV
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Weight:
53.6 kg
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Net Weight:
53.6 kg
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Product Or Component Type:
variable speed drive
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Ambient Air Temperature For Storage:
-40-70°C
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Range Of Product:
Altivar Process ATV900
With Safety Function Safe Operating Stop (Sos):
FALSE
Motor Power Kw:
55.0 kW normal duty || 45.0 kW heavy duty
Relative Symmetric Network Frequency Tolerance:
0.05
Upgradeability:
Upgraded components available
With Safety Function Safe Direction (Sdi):
FALSE
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Communication Port Protocol:
EtherNet/IP || Modbus TCP || Modbus serial
Braking To Standstill:
by DC injection
Product Specific Application:
process for industrial
Noise Level:
68.3 dB 86/188/EEC
Base Load Current At High Overload:
88.0 A
$7,654.08