Schneider Electric

Schneider Electric ATV930D75N4 Atv930 Ip21 75Kw 400V/480V Variable Spee

(No reviews yet) Write a Review
SKU:
ATV930D75N4
UPC:
3606480883408
Condition:
New
Product Specific Application:
process for industrial
Pollution Degree:
2
Prospective Line Isc:
50 kA
Type Of Polarization:
no impedance
With Safety Function Safe Direction (Sdi):
FALSE
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Brake Chopper Integrated:
TRUE
Power Dissipation In W:
natural convection 174 W 380 V 2.5 kHz || forced convection 1369 W 380 V 2.5 kHz
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Ip Degree Of Protection:
IP21
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Analogue Output Number:
2
With Safety Function Safe Programmable Logic:
FALSE
Overvoltage Category:
III
Apparent Power:
93.7 kVA 480 V normal duty) || 72.2 kVA 480 V heavy duty)
Volume Of Cooling Air:
295 m3/h
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
4 Quadrant Operation Possible:
TRUE
Device Application:
Industrial Application
Upgradeability:
Upgraded components available
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Switching Frequency:
1...8 kHz adjustable || 2.5...8 kHz with derating factor
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Continuous Output Current:
145 A 2.5 kHz normal duty || 106 A 2.5 kHz heavy duty
Relay Output Number:
3
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Number Of Addresses:
1-247 Modbus serial
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Braking To Standstill:
by DC injection
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Type Of Polarization:
no impedance Modbus serial
With Safety Function Safely Limited Speed (Sls):
TRUE
Discrete Input Number:
10
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Base Load Current At High Overload:
106.0 A
Nominal Switching Frequency:
2.5 kHz
Marking:
CE
Product Certifications:
UL || CSA || TÜV
With Safety Function Safe Operating Stop (Sos):
FALSE
Ambient Air Temperature For Storage:
-40-70 °C
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Product Destination:
synchronous motors || asynchronous motors
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Maximum Output Voltage:
480.0 V
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Mercury Free:
Yes
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Emc Filter:
integrated || with EMC plate option
Regulation Loop:
adjustable PID regulator
Variant:
standard version || with braking chopper
With Safety Function Safe Torque Off (Sto):
TRUE
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Maximum Output Frequency:
599 Hz
Width:
290 mm
Rohs Exemption Information:
Yes
Depth:
325.5 mm
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Physical Interface:
Ethernet || 2-wire RS 485
With Safety Function Safe Stop 1 (Ss1):
TRUE
Ambient Air Transport Temperature:
-40-70 °C
Motor Slip Compensation:
not available in permanent magnet motor law || adjustable || automatic whatever the load || can be suppressed
Motor Power Kw:
75.0 kW normal duty || 55.0 kW heavy duty
Data Format:
8 bits, configurable odd, even or no parity
With Safety Function Safe Position (Sp):
FALSE
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Noise Level:
68.3 dB
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Analogue Input Number:
3
Mounting Mode:
wall mount
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Range Of Product:
Altivar Process ATV900
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || DC bus screw terminal 70...120 mm² AWG 1/0...250 kcmil || line side screw terminal 95...120 mm² AWG 3/0...250 kcmil || motor screw terminal 95...120 mm² AWG 3/0...250 kcmil
Maximum Transient Current:
174 A 60 s normal duty) || 159 A 60 s heavy duty)
Number Of Addresses:
1-247
Quantity Per Set:
1
Discrete Input Logic:
16 preset speeds
With Safety Function Safely Limited Position (Slp):
FALSE
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Height:
922 mm
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity Profile:
ENVEOLI1411014EN
Isolation:
between power and control terminals
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Network Frequency:
50-60 Hz
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
China Rohs Regulation:
X
Degree Of Protection:
UL type 1
Product Or Component Type:
variable speed drive
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Assembly Style:
enclosed
Net Weight:
59 kg
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Transmission Frame:
RTU
Phase:
3 phase
Method Of Access:
slave Modbus TCP
Relative Symmetric Network Frequency Tolerance:
0.05
Base Load Current At Low Overload:
145.0 A
Discrete Output Number:
2
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Asynchronous Motor Control Profile:
variable torque standard || optimized torque mode || constant torque standard
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Communication Port Protocol:
Modbus TCP || Modbus serial || EtherNet/IP
Operating Position:
vertical +/- 10 degree
Environmental Disclosure:
ENVPEP1411014EN
Line Current:
131.3 A 380 V normal duty) || 98.9 A 380 V heavy duty) || 112.7 A 480 V normal duty) || 86.9 A 480 V heavy duty)
Noise Level:
68.3 dB 86/188/EEC
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Connector Type:
2 RJ45 || 1 RJ45
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Brochure:
View
Catalog:
View
Datasheet:
View
$13,321.15

Description

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 75kW/100HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 55kW/75HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380Vac to 480Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
View AllClose