Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Motor Power Kw:
90.0 kW normal duty || 75.0 kW heavy duty
Connector Type:
2 RJ45 || 1 RJ45
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Number Of Addresses:
1-247
Phase:
3 phase
With Safety Function Safely Limited Position (Slp):
FALSE
Depth:
307 mm
Maximum Output Voltage:
480.0 V
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
With Safety Function Safe Speed Monitor (Ssm):
FALSE
4 Quadrant Operation Possible:
TRUE
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
With Safety Function Safe Torque Off (Sto):
TRUE
Analogue Input Number:
3
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Ambient Air Transport Temperature:
-40-70 °C
Noise Level:
68.3 dB 86/188/EEC
Relative Symmetric Network Frequency Tolerance:
0.05
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Product Specific Application:
process for industrial
Power Dissipation In W:
natural convection 196 W 380 V 2.5 kHz || forced convection 1585 W 380 V 2.5 kHz
Volume Of Cooling Air:
295 m3/h
Line Current:
156.2 A 380 V normal duty) || 134.3 A 380 V heavy duty) || 135.8 A 480 V normal duty) || 118.1 A 480 V heavy duty)
Maximum Transient Current:
207.6 A 60 s normal duty) || 217.5 A 60 s heavy duty)
Regulation Loop:
adjustable PID regulator
Relay Output Number:
3
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 120 mm² AWG 4/0...250 kcmil || motor screw terminal 120 mm² 250 kcmil || DC bus screw terminal 95...120 mm² AWG 3/0...250 kcmil
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Base Load Current At High Overload:
145.0 A
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Physical Interface:
Ethernet || 2-wire RS 485
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Upgradeability:
Upgraded components available
Overvoltage Category:
III
Ambient Air Temperature For Storage:
-40-70 °C
With Sft Fct Safe Stop 2 (Ss2):
FALSE
With Safety Function Safe Operating Stop (Sos):
FALSE
Analogue Output Number:
2
With Safety Function Safe Brake Management (Sbc/Sbt):
1...8 kHz adjustable || 2.5...8 kHz with derating factor
Assembly Style:
with heat sink
Environmental Disclosure:
ENVPEP2007013EN
Brake Chopper Integrated:
TRUE
Ip Degree Of Protection:
IP21
Range Of Product:
Altivar Process ATV900
Mounting Mode:
cabinet mount
China Rohs Regulation:
X
Pollution Degree:
2
With Safety Function Safely Limited Speed (Sls):
TRUE
Operating Position:
vertical +/- 10 degree
Communication Port Protocol:
EtherNet/IP || Modbus serial || Modbus TCP
Maximum Output Frequency:
599 Hz
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Emc Filter:
integrated || with EMC plate option
Width:
265 mm
Asynchronous Motor Control Profile:
constant torque standard || optimized torque mode || variable torque standard
Braking To Standstill:
by DC injection
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Device Application:
Industrial Application
Type Of Polarization:
no impedance Modbus serial
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Data Format:
8 bits, configurable odd, even or no parity
With Safety Function Safe Position (Sp):
FALSE
Apparent Power:
112.9 kVA 480 V normal duty) || 98.2 kVA 480 V heavy duty)
Discrete Output Type: