Schneider Electric ATV930U22N4ZU Atv930 T12 Rdy Ip20 3Hp 400V Wo Keypad
SKU:
ATV930U22N4ZU
UPC:
3606489740207
MPN:
Condition:
New
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Number Of Addresses:
1-247 Modbus serial
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Mounting Mode:
cabinet mount
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Pollution Degree:
2
Apparent Power:
3.2 kVA 480 V normal duty) || 2.4 kVA 480 V heavy duty)
Maximum Output Frequency:
599 Hz
Emc Filter:
integrated || with EMC plate option
Product Specific Application:
process for industrial
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Discrete Output Number:
2
Data Format:
8 bits, configurable odd, even or no parity
Volume Of Cooling Air:
38 m3/h
Discrete Input Logic:
16 preset speeds
Variant:
standard version || with braking chopper
With Safety Function Safely Limited Speed (Sls):
TRUE
Maximum Output Voltage:
480.0 V
Asynchronous Motor Control Profile:
constant torque standard || optimized torque mode || variable torque standard
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Power Dissipation In W:
natural convection 30 W 380 V 4 kHz || forced convection 60 W 380 V 4 kHz
Motor Power Kw:
2.2 kW normal duty || 1.5 kW heavy duty
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Marking:
CE
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Rohs Exemption Information:
Yes
Product Destination:
synchronous motors || asynchronous motors
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Physical Interface:
Ethernet || 2-wire RS 485
Brake Chopper Integrated:
TRUE
With Safety Function Safe Position (Sp):
FALSE
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
With Safety Function Safe Direction (Sdi):
FALSE
China Rohs Regulation:
X
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Noise Level:
54.5 dB
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Base Load Current At Low Overload:
5.6 A
Discrete Input Number:
10
Ambient Air Temperature For Storage:
-40-70 °C
Type Of Polarization:
no impedance
With Safety Function Safe Brake Management (Sbc/Sbt):
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Maximum Transient Current:
6.7 A 60 s normal duty) || 6 A 60 s heavy duty)
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Isolation:
between power and control terminals
Maximum Thdi:
<48 % full load IEC 61000-3-12
With Safety Function Safe Operating Stop (Sos):
FALSE
Environmental Disclosure:
ENVPEP2007009EN
With Safety Function Safe Stop 1 (Ss1):
TRUE
With Safety Function Safely Limited Position (Slp):
FALSE
Sustainable Offer Status:
Green Premium product
Network Frequency:
50-60 Hz
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 2.5...6 mm² AWG 14...AWG 10 || motor screw terminal 2.5...6 mm² AWG 14...AWG 10 || DC bus screw terminal 2.5...6 mm² AWG 14...AWG 10
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Braking To Standstill:
by DC injection
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Operating Position:
vertical +/- 10 degree
Ambient Air Transport Temperature:
-40-70 °C
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Depth:
196 mm
Line Current:
4.3 A 380 V normal duty) || 3.1 A 380 V heavy duty) || 3.8 A 480 V normal duty) || 2.9 A 480 V heavy duty)
Motor Slip Compensation:
can be suppressed || not available in permanent magnet motor law || adjustable || automatic whatever the load
Quantity Per Set:
1
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Mercury Free:
Yes
Analogue Input Number:
3
Continuous Output Current:
5.6 A 4 kHz normal duty || 4 A 4 kHz heavy duty
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Method Of Access:
slave Modbus TCP
Width:
130 mm
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Communication Port Protocol:
Modbus TCP || EtherNet/IP || Modbus serial
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov