Schneider Electric ATV930U22S6X Atv930 Ip21 3Hp 600V Variateur De Vit.

(No reviews yet) Write a Review
SKU:
ATV930U22S6X
UPC:
3.60648E+12
Condition:
New
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Physical Interface:
Ethernet || 2-wire RS 485
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Noise Level:
56 dB
Nominal Switching Frequency:
4 kHz
Circularity Profile:
ENVEOLI1707007EN
With Safety Function Safe Direction (Sdi):
FALSE
Maximum Output Voltage:
600.0 V
Sustainable Offer Status:
Green Premium product
Motor Slip Compensation:
can be suppressed || adjustable || not available in permanent magnet motor law || automatic whatever the load
Variant:
standard version || with braking chopper
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Phase:
3 phase
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
With Safety Function Safely Limited Speed (Sls):
TRUE
Noise Level:
56 dB 86/188/EEC
Quantity Per Set:
1
Isolation:
between power and control terminals
With Safety Function Safe Position (Sp):
FALSE
Method Of Access:
slave Modbus TCP
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 6...10 mm² AWG 10...AWG 8 || line side screw terminal 6 mm² AWG 10 || DC bus screw terminal 6 mm² AWG 10
Maximum Output Frequency:
599 Hz
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Ambient Air Temperature For Storage:
-40-70 °C
Communication Port Protocol:
Modbus TCP || EtherNet/IP || Modbus serial
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
[Us] Rated Supply Voltage:
600 V - 15...10 %
Upgradeability:
Upgraded components available
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Number Of Addresses:
1-247
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immu
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Width:
171 mm
With Safety Function Safe Torque Off (Sto):
TRUE
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Base Load Current At High Overload:
3.1 A
Range Of Product:
Altivar Process ATV900
Continuous Output Current:
4.2 A 4 kHz normal duty || 3.1 A 4 kHz heavy duty
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Degree Of Protection:
UL type 1
Pollution Degree:
2
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s || S, U or customized
Ambient Air Transport Temperature:
-40-70 °C
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Ip Degree Of Protection:
IP21
Mounting Mode:
wall mount
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Network Frequency:
50-60 Hz
Regulation Loop:
adjustable PID regulator
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Discrete Output Number:
2
Rohs Exemption Information:
Yes
Analogue Input Number:
3
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Mercury Free:
Yes
Relative Symmetric Network Frequency Tolerance:
0.05
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Type Of Polarization:
no impedance Modbus serial
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Data Format:
8 bits, configurable odd, even or no parity
Depth:
236 mm
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Type Of Polarization:
no impedance
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
4 Quadrant Operation Possible:
TRUE
Volume Of Cooling Air:
103 m3/h
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Analogue Output Number:
2
With Safety Function Safely Limited Position (Slp):
FALSE
Overvoltage Category:
III
Discrete Input Number:
10
Height:
409 mm
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Connector Type:
2 RJ45 || 1 RJ45
Device Application:
Industrial Application
Base Load Current At Low Overload:
4.2 A
Product Destination:
synchronous motors || asynchronous motors
Discrete Input Logic:
16 preset speeds
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
With Safety Function Safe Operating Stop (Sos):
FALSE
Product Certifications:
TÜV || CSA || UL
Operating Position:
vertical +/- 10 degree
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Transmission Frame:
RTU
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Emc Filter:
integrated || with EMC plate option
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
China Rohs Regulation:
X
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Prospective Line Isc:
70 kA
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Product Or Component Type:
variable speed drive
Environmental Disclosure:
ENVPEP1707007EN
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
With Safety Function Safe Stop 1 (Ss1):
TRUE
Braking To Standstill:
by DC injection
Product Specific Application:
process for industrial
Maximum Transient Current:
5.04 A 60 s normal duty) || 4.7 A 60 s heavy duty)
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Net Weight:
5.5 kg
Power Dissipation In W:
forced convection 31 W 600 V 4 kHz || natural convection 82 W 600 V 4 kHz
Assembly Style:
enclosed
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Local Signalling:
local diagnostic 3 LED mono/dual colour) || presence of voltage 1 LED red) || embedded communication status 3 LED dual colour) || communication module status 4 LED dual colour)
With Safety Function Safe Programmable Logic:
FALSE
Relay Output Number:
3
Number Of Addresses:
1-247 Modbus serial
Brake Chopper Integrated:
TRUE
Apparent Power:
3 kVA 600 V normal duty) || 2.2 kVA 600 V heavy duty)
  • Schneider Electric ATV930U22S6X Atv930 Ip21 3Hp 600V Variateur De Vit.
  • Schneider Electric ATV930U22S6X Atv930 Ip21 3Hp 600V Variateur De Vit.
$2,359.53