Schneider Electric

Schneider Electric ATV930U55S6X Atv930 Ip21 7.5Hp 600V Variateur De Vit.

(No reviews yet) Write a Review
SKU:
ATV930U55S6X
UPC:
3.60648E+12
Condition:
New
Product Or Component Type:
variable speed drive
Ambient Air Transport Temperature:
-40-70 °C
Circularity Profile:
ENVEOLI1707007EN
Physical Interface:
Ethernet || 2-wire RS 485
Sustainable Offer Status:
Green Premium product
Assembly Style:
enclosed
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Transmission Frame:
RTU
Analogue Input Number:
3
Operating Position:
vertical +/- 10 degree
Upgradeability:
Upgraded components available
Discrete Input Number:
10
Acceleration And Deceleration Ramps:
S, U or customized || linear adjustable separately from 0.01...9999 s
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Network Frequency:
50-60 Hz
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Variant:
standard version || with braking chopper
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Type Of Polarization:
no impedance Modbus serial
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Braking To Standstill:
by DC injection
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
China Rohs Regulation:
X
Range Of Product:
Altivar Process ATV900
Data Format:
8 bits, configurable odd, even or no parity
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
[Us] Rated Supply Voltage:
600 V - 15...10 %
Volume Of Cooling Air:
103 m3/h
4 Quadrant Operation Possible:
TRUE
Isolation:
between power and control terminals
Number Of Addresses:
1-247
Rohs Exemption Information:
Yes
Regulation Loop:
adjustable PID regulator
Continuous Output Current:
7.2 A 4 kHz heavy duty || 9.5 A 4 kHz normal duty
Net Weight:
5.5 kg
Analogue Output Number:
2
Device Application:
Industrial Application
Environmental Disclosure:
ENVPEP1707007EN
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Mounting Mode:
wall mount
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Power Dissipation In W:
forced convection 74 W 600 V 4 kHz || natural convection 102 W 600 V 4 kHz
Product Specific Application:
process for industrial
Motor Slip Compensation:
not available in permanent magnet motor law || can be suppressed || automatic whatever the load || adjustable
Maximum Output Voltage:
600.0 V
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Brake Chopper Integrated:
TRUE
Height:
409 mm
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
With Safety Function Safe Torque Off (Sto):
TRUE
With Safety Function Safe Programmable Logic:
FALSE
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Overvoltage Category:
III
Ambient Air Temperature For Storage:
-40-70 °C
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Depth:
236 mm
Type Of Polarization:
no impedance
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Quantity Per Set:
1
With Safety Function Safely Limited Position (Slp):
FALSE
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Connector Type:
2 RJ45 || 1 RJ45
Maximum Output Frequency:
599 Hz
Degree Of Protection:
UL type 1
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
With Safety Function Safe Direction (Sdi):
FALSE
Method Of Access:
slave Modbus TCP
Discrete Input Logic:
16 preset speeds
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Prospective Line Isc:
70 kA
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Noise Level:
56 dB 86/188/EEC
Communication Port Protocol:
Modbus TCP || EtherNet/IP || Modbus serial
Product Destination:
synchronous motors || asynchronous motors
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Discrete Output Number:
2
With Safety Function Safe Operating Stop (Sos):
FALSE
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Nominal Switching Frequency:
4 kHz
Relative Symmetric Network Frequency Tolerance:
0.05
Asynchronous Motor Control Profile:
optimized torque mode || constant torque standard || variable torque standard
Maximum Transient Current:
10.8 A 60 s heavy duty) || 11.4 A 60 s normal duty)
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Product Certifications:
CSA || UL || TÜV
Phase:
3 phase
Mercury Free:
Yes
Ip Degree Of Protection:
IP21
With Safety Function Safe Stop 1 (Ss1):
TRUE
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Number Of Addresses:
1-247 Modbus serial
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Base Load Current At High Overload:
7.2 A
Noise Level:
56 dB
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Pollution Degree:
2
Width:
171 mm
Emc Filter:
integrated || with EMC plate option
Relay Output Number:
3
Local Signalling:
local diagnostic 3 LED mono/dual colour) || presence of voltage 1 LED red) || embedded communication status 3 LED dual colour) || communication module status 4 LED dual colour)
Base Load Current At Low Overload:
9.5 A
With Safety Function Safe Position (Sp):
FALSE
With Safety Function Safely Limited Speed (Sls):
TRUE
Apparent Power:
7.3 kVA 600 V normal duty) || 5.5 kVA 600 V heavy duty)
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 6...10 mm² AWG 10...AWG 8 || line side screw terminal 6 mm² AWG 10 || DC bus screw terminal 6 mm² AWG 10
Datasheet:
View
$3,106.71