Schneider Electric ATV930U75M3 Atv930 Ip21 7,5Kw 200V/240V Variable Spe

(No reviews yet) Write a Review
SKU:
ATV930U75M3
UPC:
3606480883606
Condition:
New
Product Or Component Type:
variable speed drive
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Braking To Standstill:
by DC injection
Discrete Input Number:
10
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Overvoltage Category:
III
Phase:
3 phase
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
With Sft Fct Safe Stop 2 (Ss2):
FALSE
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Product Destination:
synchronous motors || asynchronous motors
Motor Slip Compensation:
adjustable || can be suppressed || automatic whatever the load || not available in permanent magnet motor law
Pollution Degree:
2
Base Load Current At High Overload:
25.4 A
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Noise Level:
59.5 dB
Method Of Access:
slave Modbus TCP
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Upgradeability:
Upgraded components available
Base Load Current At Low Overload:
32.7 A
Connector Type:
2 RJ45 || 1 RJ45
Variant:
with braking chopper || standard version
Ambient Air Temperature For Storage:
-40-70 °C
Operating Position:
vertical +/- 10 degree
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Nominal Switching Frequency:
4 kHz
Ip Degree Of Protection:
IP21
Data Format:
8 bits, configurable odd, even or no parity
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Quantity Per Set:
1
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Discrete Output Number:
2
With Safety Function Safe Direction (Sdi):
FALSE
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
4 Quadrant Operation Possible:
TRUE
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Physical Interface:
Ethernet || 2-wire RS 485
Width:
211 mm
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Relative Symmetric Network Frequency Tolerance:
0.05
Degree Of Protection:
UL type 1
Device Application:
Industrial Application
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Mounting Mode:
wall mount
Number Of Addresses:
1-247 Modbus serial
Transmission Frame:
RTU
With Safety Function Safely Limited Position (Slp):
FALSE
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
With Safety Function Safe Stop 1 (Ss1):
TRUE
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Net Weight:
13.8 kg
Circularity Profile:
ENVEOLI1404008EN
Ambient Air Transport Temperature:
-40-70 °C
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Maximum Transient Current:
39.2 A 60 s normal duty) || 38.1 A 60 s heavy duty)
Maximum Output Voltage:
240.0 V
Number Of Addresses:
1-247
Assembly Style:
enclosed
China Rohs Regulation:
X
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Maximum Output Frequency:
599 Hz
Prospective Line Isc:
50 kA
Analogue Input Number:
3
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Emc Filter:
integrated || with EMC plate option
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Regulation Loop:
adjustable PID regulator
Depth:
235 mm
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Apparent Power:
9.9 kVA 240 V normal duty) || 7.6 kVA 240 V heavy duty)
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Rohs Exemption Information:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
With Safety Function Safe Operating Stop (Sos):
FALSE
With Safety Function Safe Torque Off (Sto):
TRUE
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Noise Level:
59.5 dB 86/188/EEC
Discrete Input Logic:
16 preset speeds
Product Certifications:
UL || CSA || TÜV
Network Frequency:
50-60 Hz
Continuous Output Current:
32.7 A 4 kHz normal duty || 25.4 A 4 kHz heavy duty
Relay Output Number:
3
With Safety Function Safely Limited Speed (Sls):
TRUE
Height:
545.9 mm
Brake Chopper Integrated:
TRUE
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Volume Of Cooling Air:
103 m3/h
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Range Of Product:
Altivar Process ATV900
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Product Specific Application:
process for industrial
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Type Of Polarization:
no impedance Modbus serial
Type Of Polarization:
no impedance
Power Dissipation In W:
forced convection 310 W 200 V 4 kHz || natural convection 51 W 200 V 4 kHz
Analogue Output Number:
2
With Safety Function Safe Position (Sp):
FALSE
Motor Power Kw:
7.5 kW normal duty || 5.5 kW heavy duty
Environmental Disclosure:
ENVPEP1404008EN
With Safety Function Safe Programmable Logic:
FALSE
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 10...16 mm² AWG 8...AWG 6 || motor screw terminal 10...16 mm² AWG 8...AWG 6 || DC bus screw terminal 10...16 mm² AWG 8...AWG 6
Isolation:
between power and control terminals
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Marking:
CE
Line Current:
27.1 A 200 V normal duty) || 20.1 A 200 V heavy duty) || 22.6 A 240 V normal duty) || 16.9 A 240 V heavy duty)
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Communication Port Protocol:
Modbus serial || EtherNet/IP || Modbus TCP
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Brochure:
View
Datasheet:
View
  • Schneider Electric ATV930U75M3 Atv930 Ip21 7,5Kw 200V/240V Variable Spe
  • Schneider Electric ATV930U75M3 Atv930 Ip21 7,5Kw 200V/240V Variable Spe
  • Schneider Electric ATV930U75M3 Atv930 Ip21 7,5Kw 200V/240V Variable Spe
$3,197.01

Description

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 7.5kW/10HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 5.5kW/7.5HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 200Vac to 240Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
View AllClose