Schneider Electric ATV950D11N4EU Atv950 Ip55 Ultype12 11Kw 400V/480V With

(No reviews yet) Write a Review
SKU:
ATV950D11N4EU
UPC:
3606481284440
Condition:
New
Variant:
with load break switch || with braking chopper
Connector Type:
2 RJ45 || 1 RJ45
Transmission Frame:
RTU
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Regulation Loop:
adjustable PID regulator
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Noise Level:
52 dB
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Rohs Exemption Information:
Yes
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Noise Level:
52 dB 86/188/EEC
Analogue Input Number:
3
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Upgradeability:
Upgraded components available
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
With Safety Function Safe Direction (Sdi):
FALSE
Mercury Free:
Yes
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
With Safety Function Safe Operating Stop (Sos):
FALSE
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Type Of Polarization:
no impedance Modbus serial
Network Frequency:
50-60 Hz
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Base Load Current At High Overload:
16.5 A
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Nominal Switching Frequency:
4 kHz
Isolation:
between power and control terminals
Degree Of Protection:
UL type 12
With Safety Function Safe Stop 1 (Ss1):
TRUE
Transmission Rate:
10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Height:
678 mm
Width:
264 mm
With Safety Function Safe Torque Off (Sto):
TRUE
Line Current:
19.8 A 380 V normal duty) || 14.1 A 380 V heavy duty) || 17.0 A 480 V normal duty) || 12.5 A 480 V heavy duty)
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Depth:
330 mm
Apparent Power:
14.1 kVA 480 V normal duty) || 10.4 kVA 480 V heavy duty)
With Safety Function Safely Limited Speed (Sls):
TRUE
With Safety Function Safe Speed Monitor (Ssm):
FALSE
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
With Sft Fct Safe Stop 2 (Ss2):
FALSE
With Safety Function Safely Limited Position (Slp):
FALSE
Ip Degree Of Protection:
IP55
Phase:
3 phase
Electrical Connection:
control screw terminal 0.5...1.5 mm² || line side screw terminal 6 mm² || motor screw terminal 6...10 mm² || DC bus screw terminal 6...10 mm²
Product Certifications:
DNV-GL || TÜV || Bureau Veritas || ATEX INERIS || ABS || UL || CSA
Communication Port Protocol:
Modbus serial || Modbus TCP || EtherNet/IP
Overvoltage Category:
III
Discrete Output Number:
2
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Product Or Component Type:
variable speed drive
Emc Filter:
integrated || with EMC plate option
Product Destination:
synchronous motors || asynchronous motors
Assembly Style:
enclosed
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
4 Quadrant Operation Possible:
TRUE
China Rohs Regulation:
X
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Maximum Transient Current:
28.2 A 60 s normal duty) || 24.8 A 60 s heavy duty)
Brake Chopper Integrated:
TRUE
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Transmission Rate:
10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Mounting Mode:
wall mount
Continuous Output Current:
23.5 A 4 kHz normal duty || 16.5 A 4 kHz heavy duty
With Safety Function Safe Position (Sp):
FALSE
Relative Symmetric Network Frequency Tolerance:
0.05
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Braking To Standstill:
by DC injection
Data Format:
8 bits, configurable odd, even or no parity
Prospective Line Isc:
50 kA
Base Load Current At Low Overload:
23.5 A
Maximum Output Frequency:
599 Hz
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Input Compatibility:
DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Standards:
UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Quantity Per Set:
1
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
With Safety Function Safe Programmable Logic:
FALSE
Type Of Polarization:
no impedance
Marking:
CE
Range Of Product:
Altivar Process ATV900
Discrete Input Logic:
16 preset speeds
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Analogue Output Number:
2
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Relay Output Number:
3
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Product Specific Application:
process for industrial
Operating Position:
vertical +/- 10 degree
Number Of Addresses:
1-247
Physical Interface:
Ethernet || 2-wire RS 485
Sustainable Offer Status:
Green Premium product
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Maximum Output Voltage:
480.0 V
Device Application:
Industrial Application
Method Of Access:
slave Modbus TCP
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Asynchronous Motor Control Profile:
constant torque standard || variable torque standard || optimized torque mode
Number Of Addresses:
1-247 Modbus serial
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Ambient Air Temperature For Operation:
-15-40 °C without derating) || 40-50 °C with derating factor)
Motor Power Kw:
11.0 kW normal duty || 7.5 kW heavy duty
Net Weight:
13.7 kg
Pollution Degree:
2
Environmental Disclosure:
ENVPEP1508009EN
Circularity Profile:
ENVEOLI1508009EN
Ambient Air Transport Temperature:
-40-70 °C
Discrete Input Number:
10
Ambient Air Temperature For Storage:
-40-70 °C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Motor Slip Compensation:
not available in permanent magnet motor law || automatic whatever the load || can be suppressed || adjustable
Datasheet:
View
$6,646.59

Description

variable speed drive, Altivar Process ATV900, ATV950, 11kW, 15hp, 380 to 480V, IP55, UL type12, disconnect switch