Schneider Electric BDA260401 Molded Case Circuit Brkr 600Y/347V 40A

(No reviews yet) Write a Review
SKU:
BDA260401
UPC:
3606481152138
Condition:
New
Net Weight:
0.952 kg
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Circuit Breaker Application:
HACR rated
Ik Degree Of Protection:
IK07 IEC 62262
Trip Unit Technology:
thermal-magnetic
Continuous Current Rating:
0.8
Utilisation Category:
category A
Poles Description:
2P
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Device Application:
distribution
Mounting Height:
76.2 mm
Product Name:
PowerPact B
Ambient Air Temperature For Operation:
-25-70 °C
Phase Connection:
AB
Electrical Connection:
I-Line connection, line || lugs, load
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Wire Stripping Length:
20 mm
Network Frequency:
50/60 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Suitability For Isolation:
yes IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Height:
137 mm
Pollution Degree:
3 IEC 60947-1
Quality Labels:
CE
Quantity Per Set:
set of 1
Mercury Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Mode:
I-Line
Depth:
89 mm
Pvc Free:
Yes
Rohs Exemption Information:
Yes
Ip Degree Of Protection:
front cover IP40 IEC 60529
Standards:
CSA C22.2 No 5 || UL 489 || NMX J-266 || EN/IEC 60947-2 || GB 14048.2 || EN/IEC 60947-5-1 || NEMA AB1
Circularity Profile:
N/A
Breaking Capacity Code:
D
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Line Rated Current:
40-40 A
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Range:
PowerPact
Width:
54 mm
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Halogen Content Performance:
Halogen free product
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Local Signalling:
presence of auxiliary contacts flag green)
Ambient Air Temperature For Storage:
-50-85 °C
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
9 Mm Pitches:
6
Control Type:
toggle
Product Or Component Type:
circuit breaker
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Color:
Gray RAL 7016)
Device Short Name:
BD 040
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Connection Pitch:
27 mm
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Eu Rohs Directive:
Compliant with Exemptions
Environmental Disclosure:
ENVPEP1610005EN
Sustainable Offer Status:
Green Premium product
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BDA260401 Molded Case Circuit Brkr 600Y/347V 40A
  • Schneider Electric BDA260401 Molded Case Circuit Brkr 600Y/347V 40A
  • Schneider Electric BDA260401 Molded Case Circuit Brkr 600Y/347V 40A
$810.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 40A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose