Schneider Electric BDA260901 Molded Case Circuit Brkr 600Y/347V 90A

(No reviews yet) Write a Review
SKU:
BDA260901
UPC:
785901049043
Condition:
New
Range:
PowerPact
Product Or Component Type:
circuit breaker
Continuous Current Rating:
0.8
Sustainable Offer Status:
Green Premium product
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Ik Degree Of Protection:
IK07 IEC 62262
Line Rated Current:
90-90 A
Wire Stripping Length:
20 mm
[Ics] Rated Service Breaking Capacity:
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Net Weight:
0.952 kg
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Device Application:
distribution
Poles Description:
2P
Circuit Breaker Application:
HACR rated
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
Quantity Per Set:
set of 1
Quality Labels:
CE
Halogen Content Performance:
Halogen free product
Mounting Mode:
I-Line
Eu Rohs Directive:
Compliant
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Ambient Air Temperature For Storage:
-50-85 °C
Height:
137 mm
Mercury Free:
Yes
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Depth:
89 mm
Connection Pitch:
27 mm
Standards:
UL 489 || CSA C22.2 No 5 || NMX J-266 || EN/IEC 60947-5-1 || EN/IEC 60947-2 || NEMA AB1 || GB 14048.2
Mounting Height:
76.2 mm
Trip Unit Technology:
thermal-magnetic
Width:
54 mm
Pollution Degree:
3 IEC 60947-1
Phase Connection:
AB
Utilisation Category:
category A
Product Name:
PowerPact B
Rohs Exemption Information:
Yes
Network Frequency:
50/60 Hz
Breaking Capacity Code:
D
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity:
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
Ambient Air Temperature For Operation:
-25-70 °C
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Pvc Free:
Yes
Color:
Gray RAL 7016)
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
9 Mm Pitches:
6
Suitability For Isolation:
yes IEC 60947-2
Control Type:
toggle
Device Short Name:
BD 090
Environmental Disclosure:
ENVPEP1610005EN
Ip Degree Of Protection:
front cover IP40 IEC 60529
[Ue] Rated Operational Voltage:
525 V AC 50/60 Hz UL 489
Local Signalling:
presence of auxiliary contacts flag green)
Electrical Connection:
I-Line connection, line || lugs, load
  • Schneider Electric BDA260901 Molded Case Circuit Brkr 600Y/347V 90A
  • Schneider Electric BDA260901 Molded Case Circuit Brkr 600Y/347V 90A
  • Schneider Electric BDA260901 Molded Case Circuit Brkr 600Y/347V 90A
$1,470.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 90A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose