Schneider Electric BGA161255 Molded Case Circuit Breaker 347V 125A
Schneider Electric
$1,369.50
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 125A, 1 pole, circuit breaker has a breaking capacity of 18kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with a C phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Ambient Air Temperature For Storage:
- -50-85 °C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Net Weight:
- 0.6375 kg
- Circularity Profile:
- N/A
- Standards:
- GB 14048.2 || NEMA AB1 || EN/IEC 60947-2 || CSA C22.2 No 5 || EN/IEC 60947-5-1 || NMX J-266 || UL 489
- Device Short Name:
- BG 125
- Network Frequency:
- 50/60 Hz
- Breaking Capacity Code:
- G
- Quality Labels:
- CE
- Pollution Degree:
- 3 IEC 60947-1
- Poles Description:
- 1P
- Local Signalling:
- presence of auxiliary contacts flag green)
- Phase Connection:
- C
- 9 Mm Pitches:
- 3
- Trip Unit Technology:
- thermal-magnetic
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Width:
- 27 mm
- Mounting Height:
- 38.1 mm
- Sustainable Offer Status:
- Green Premium product
- Device Application:
- distribution
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Line Rated Current:
- 125-125 A
- Eu Rohs Directive:
- Compliant with Exemptions
- Connection Pitch:
- 27 mm
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Mercury Free:
- Yes
- Ik Degree Of Protection:
- IK07 IEC 62262
- Range:
- PowerPact
- Suitability For Isolation:
- yes IEC 60947-2
- Pvc Free:
- Yes
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2
- [Ue] Rated Operational Voltage:
- 240 V AC 50/60 Hz UL 489
- Electrical Connection:
- I-Line connection, line || lugs, load
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Control Type:
- toggle
- Color:
- Gray RAL 7016)
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Product Or Component Type:
- circuit breaker
- Circuit Breaker Application:
- HACR rated
- Product Name:
- PowerPact B
- Mounting Mode:
- I-Line
- Ambient Air Temperature For Operation:
- -25-70 °C
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Halogen Content Performance:
- Halogen free product
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Quantity Per Set:
- set of 1
- Utilisation Category:
- category A
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Environmental Disclosure:
- ENVPEP1610005EN
- Wire Stripping Length:
- 20 mm
- Height:
- 137 mm
- Breaking Capacity:
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480Y/277 V AC 50/60 Hz UL 489 || 18 kA 600Y/347 V AC 50/60 Hz UL 489 || 20 kA 125 V DC UL 489
- Rohs Exemption Information:
- Yes
- Continuous Current Rating:
- 0.8
- Depth:
- 89 mm
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View