- Number Of Slots:
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- Electrical Durability:
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Mechanical Durability:
- 20000 cycles IEC 947-1 Annex K ed 5.2
- Color:
- Gray RAL 7016)
- Device Application:
- distribution
- Standards:
- EN/IEC 60947-5-1 || NEMA AB1 || NMX J-266 || GB 14048.2 || UL 489 || CSA C22.2 No 5 || EN/IEC 60947-2
- Mercury Free:
- Yes
- Depth:
- 89 mm
- Device Short Name:
- BG 035
- Awg Gauge:
- AWG 14...AWG 2/0 aluminium/copper
- Breaking Capacity:
- 65 kA 208Y/120 V AC 50/60 Hz UL 489 || 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480/277 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 250 V DC UL 489 || 20 kA 600Y/347 V AC 50/60 Hz UL 489
- Ambient Air Temperature For Operation:
- -25-70 °C
- Product Name:
- PowerPact B
- Pollution Degree:
- 3 IEC 60947-1
- Network Frequency:
- 50/60 Hz
- Breaking Capacity Code:
- G
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Wire Stripping Length:
- 20 mm
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Connection Pitch:
- 27 mm
- [Ui] Rated Insulation Voltage:
- 800 V IEC 60947-2
- Product Certifications:
- UL || IEC || CCC || EAC || CSA || NOM
- Line Rated Current:
- 35-35 A
- Sustainable Offer Status:
- Green Premium product
- Mounting Mode:
- I-Line
- Electrical Connection:
- I-Line connection, line || lugs, load
- Mounting Height:
- 76.2 mm
- Control Type:
- toggle
- Tightening Torque:
- 3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
- Local Signalling:
- presence of auxiliary contacts flag green)
- [Ue] Rated Operational Voltage:
- 525 V AC 50/60 Hz UL 489
- Rohs Exemption Information:
- Yes
- Poles Description:
- 2P
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 35 kA 440 V AC 50/60 Hz IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Quality Labels:
- CE
- Suitability For Isolation:
- yes IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Product Or Component Type:
- circuit breaker
- Width:
- 54 mm
- Phase Connection:
- AB
- Pvc Free:
- Yes
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Ik Degree Of Protection:
- IK07 IEC 62262
- Circuit Breaker Application:
- HACR rated
- Height:
- 137 mm
- Utilisation Category:
- category A
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Halogen Content Performance:
- Halogen free product
- Eu Rohs Directive:
- Compliant
- Range:
- PowerPact
- Continuous Current Rating:
- 0.8
- Environmental Disclosure:
- ENVPEP1610005EN
- Net Weight:
- 0.952 kg
- 9 Mm Pitches:
- 6
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ambient Air Temperature For Storage:
- -50-85 °C
- Quantity Per Set:
- set of 1
- QN-QUOTE-REQUEST:
- true