Schneider Electric BJA36015 Molded Case Circuit Brkr 600Y/347V 15A

(No reviews yet) Write a Review
SKU:
BJA36015
UPC:
3606481154217
Condition:
New
Breaking Capacity:
100 kA 208Y/120 V AC 50/60 Hz UL 489 || 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480/277 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600Y/347 V AC 50/60 Hz UL 489 || 50 kA 250 V DC UL 489
Network Frequency:
50/60 Hz
Suitability For Isolation:
yes IEC 60947-2
Connection Pitch:
27 mm
Product Name:
PowerPact B
Mounting Mode:
I-Line
Control Type:
toggle
Trip Unit Technology:
thermal-magnetic
Poles Description:
3P
Electrical Connection:
I-Line connection, line || lugs, load
[Ics] Rated Service Breaking Capacity:
100 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 10 kA 690 V AC 50/60 Hz IEC 60947-2 || 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 65 kA 440 V AC 50/60 Hz IEC 60947-2
Range:
PowerPact
Ambient Air Temperature For Operation:
-25-70 °C
Depth:
89 mm
Net Weight:
1.315 kg
Device Short Name:
BJ 015
Pvc Free:
Yes
Rohs Exemption Information:
Yes
Pollution Degree:
3 IEC 60947-1
Product Or Component Type:
circuit breaker
Mechanical Durability:
20000 cycles IEC 947-1 Annex K ed 5.2
Number Of Slots:
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity Code:
J
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Device Application:
distribution
Utilisation Category:
category A
Width:
81 mm
Ik Degree Of Protection:
IK07 IEC 62262
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz UL 489
Product Certifications:
UL || IEC || CCC || EAC || CSA || NOM
Eu Rohs Directive:
Compliant with Exemptions
Quality Labels:
CE
Awg Gauge:
AWG 14...AWG 2/0 aluminium/copper
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Standards:
NMX J-266 || EN/IEC 60947-5-1 || GB 14048.2 || EN/IEC 60947-2 || UL 489 || CSA C22.2 No 5 || NEMA AB1
Ip Degree Of Protection:
front cover IP40 IEC 60529
Continuous Current Rating:
0.8
Tightening Torque:
3.6-4.4 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5-6.2 N.m 10-70 mm² (AWG 8...AWG 2/0)
Phase Connection:
ABC
Mercury Free:
Yes
Halogen Content Performance:
Halogen free product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Line Rated Current:
15-15 A
Wire Stripping Length:
20 mm
Quantity Per Set:
set of 1
Electrical Durability:
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP1610005EN
Ambient Air Temperature For Storage:
-50-85 °C
Sustainable Offer Status:
Green Premium product
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Color:
Gray RAL 7016)
Mounting Height:
114 mm
Height:
137 mm
9 Mm Pitches:
9
Circularity Profile:
N/A
Circuit Breaker Application:
HACR rated
[Ui] Rated Insulation Voltage:
800 V IEC 60947-2
Local Signalling:
presence of auxiliary contacts flag green)
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric BJA36015 Molded Case Circuit Brkr 600Y/347V 15A
  • Schneider Electric BJA36015 Molded Case Circuit Brkr 600Y/347V 15A
  • Schneider Electric BJA36015 Molded Case Circuit Brkr 600Y/347V 15A
$1,928.00

Description

PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 15A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose