Schneider Electric

Schneider Electric CR1F185Q7 Magnetic latching contactor,TeSys F,3P(3NO),AC-3 <=440V 185A,380-400V AC coil

(No reviews yet) Write a Review
SKU:
CR1F185Q7
MPN:
CR1F185Q7
Condition:
New
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-15-70°C
Tightening Torque:
18 N.m
[Ie] Rated Operational Current:
185 A (at <40°C) at <= 440 V AC AC-3 || 275 A (at <40°C) at <= 440 V AC AC-1 || 170 A (at <40°C) at <= 440 V AC AC-4
[Uc] Control Circuit Voltage:
380 V AC 50/60 Hz
Product Name:
TeSys F
Motor Power Kw:
90 kW at 400 V AC 50/60 Hz (AC-4)
Contactor Application:
motor control || resistive load
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Rated Breaking Capacity:
1800 A at 220...440 V || 1600 A at 500 V || 600 A at 1000 V || 1200 A at 660/690 V
Pole Contact Composition:
3 NO
Standards:
EN/IEC 60947-1 || EN/IEC 60947-4-1 || JIS C8201-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
Control Circuit Type:
AC 50/60 Hz
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ui] Rated Insulation Voltage:
1000 V IEC 60158-1 || 1000 V IEC 60947-4 || 1000 V BS 775 || 1500 V VDE 0110 group C
Irms Rated Making Capacity:
2100 A
Product Certifications:
CB Scheme || UL || CSA || EAC || CE || UKCA
Country of Origin:
Czechia
Protective Treatment:
TC
Range:
TeSys
Average Impedance:
0.36 mOhm - Ith 275 A 50 Hz
Associated Fuse Rating:
200 A aM at <= 440 V || 315 A BS88 at <= 440 V || 315 A gG at <= 440 V
Operating Time:
35...40 ms latching || 50...100 ms unlatching
Depth:
181 mm
Maximum Operating Rate:
120 cyc/h 40°C
Eu Rohs Directive:
Compliant with Exemptions
Ambient Air Temperature For Storage:
-60-80°C
Warranty:
18 months
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mercury Free:
Yes
Average Coil Consumption:
1600 VA AC 50/60 Hz latching || 8 VA AC 50/60 Hz unlatching
Power Dissipation Per Pole:
12 W AC-3 || 26 W AC-1
Poles Description:
3P
Operating Altitude:
9842.52 ft (3000 m) without derating
Mechanical Durability:
1 Mcycles
Device Short Name:
CR1F
Control Circuit Voltage Limits:
latching: 0.85...1.1 Uc || unlatching: 0.85...1.1 Uc
[Ue] Rated Operational Voltage:
1000 V AC 25...200 Hz
Net Weight:
4.6 kg
Device Application:
control
Utilisation Category:
AC-3 || AC-1 || AC-4
[Icw] Rated Short-Time Withstand Current:
1500 A 40°C - 1 s || 1500 A 40°C - 5 s || 1500 A 40°C - 10 s || 920 A 40°C - 30 s || 740 A 40°C - 1 min || 500 A 40°C - 3 min || 400 A 40°C - 10 min
Pvc Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connections - Terminals:
bars 2 25 x 3 mm || lugs-ring terminals 1 150-150 mm² || connector 1 150-150 mm² || power circuit bolted connection
Product Or Component Type:
magnetic latching contactor
$1,847.00

Description

TeSys F magnetic latching contactor, 3 poles (3NO), 185A/1000V AC-3, for motor applications up to 90kW@400V. It provides a double coil 380-400V AC (50-60Hz) for latching and unlatching, bolt terminals for bars or cables with lugs. Supply to the coils must be applied by pulsed contacts leading to energy saving and no sensibility to interferences for contactors remaining in closed state for long periods. For operating rates until 120 cycles/hour and environments until 70°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks (instantaneous and time delay auxiliary contacts, suppressor blocks) and connection accessories (to be ordered separately). It conforms to IEC 60158-1 and IEC 60947-4, Green Premium product (RoHS/REACh).