Schneider Electric EDB24020CA Miniature Circuit Breaker 480Y/277V 20A

(No reviews yet) Write a Review
SKU:
EDB24020CA
UPC:
785901526131
Condition:
New
Product Or Component Type:
miniature circuit-breaker
Width:
1.96 in
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
cULus
Trip Unit Rating:
875-875 A
Local Signalling:
trip indicator
Breaking Capacity Code:
D
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Range Of Product:
125 A Frame EDB-EGB-EJB
Device Short Name:
EDB
Net Weight:
3 lb(US)
Electrical Connection:
lugs aluminium
Number Of Poles:
2
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Ambient Air Temperature For Operation:
50 °C
Trip Unit Technology:
thermal-magnetic
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Circuit Breaker Application:
HID rated || HACR rated
Number Of Spaces:
2
Module Type:
E-Frame
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
4.05 in
Holding Current:
270 A
Warranty:
18 months
[Ue] Rated Operational Voltage:
480Y/277 V AC
Product Destination:
NF panelboard
Number Of Spaces Required:
2
Mounting Mode:
bolt-on
Height:
5.66 in
Mercury Free:
Yes
Protection Type:
short-circuit || overload
Line Rated Current:
20 A
Rohs Exemption Information:
Yes
$643.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 50 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.