Schneider Electric EGB36035 Miniature Circuit Breaker 600V 35A

(No reviews yet) Write a Review
SKU:
EGB36035
UPC:
785901406686
Condition:
New
Module Type:
E-Frame
Warranty:
18 months
Ambient Air Temperature For Operation:
40 °C
Trip Unit Rating:
1800-1800 A
Device Short Name:
EGB
Trip Unit Technology:
thermal-magnetic
Product Destination:
NF panelboard
Product Or Component Type:
circuit-breaker
Local Signalling:
trip indicator
Number Of Spaces Required:
3
Product Certifications:
cULus
Line Rated Current:
35 A
Protection Type:
overload || short-circuit
Breaking Capacity:
18 kA 600Y/347 V AC
Electrical Connection:
lugs aluminium
Circuit Breaker Application:
HACR rated
Range Of Product:
125 A Frame EDB-EGB-EJB
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Number Of Spaces:
3
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mounting Mode:
bolt-on
Number Of Poles:
3
[Ue] Rated Operational Voltage:
600Y/347 V AC
Depth:
4.05 in
Height:
5.66 in
Breaking Capacity Code:
G
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Holding Current:
630 A
Net Weight:
4 lb(US)
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Width:
2.94 in
Brochure:
View
Catalog:
View
Datasheet:
View
$1,696.50

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 35A, 3 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose