Schneider Electric EJB34050CA Miniature Circuit Breaker 480Y/277V 50A

(No reviews yet) Write a Review
SKU:
EJB34050CA
UPC:
3606486143131
Condition:
New
Number Of Poles:
3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Electrical Connection:
lugs aluminium
Range Of Product:
125 A Frame EDB-EGB-EJB
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Warranty:
18 months
Width:
2.94 in
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Trip Unit Rating:
1800-1800 A
Mercury Free:
Yes
Number Of Spaces:
3
Line Rated Current:
50 A
Protection Type:
overload || short-circuit
Net Weight:
4 lb(US)
Device Short Name:
EJB
Mounting Mode:
bolt-on
Depth:
4.05 in
Rohs Exemption Information:
Yes
Number Of Spaces Required:
3
Holding Current:
630 A
Module Type:
E-Frame
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Height:
5.66 in
Product Or Component Type:
miniature circuit-breaker
Breaking Capacity:
65 kA 277 V AC || 100 kA 240 V AC || 65 kA 480Y/277 V AC || 100 kA 120 V AC || 100 kA 120/240 V AC
Product Certifications:
cULus
Product Destination:
NF panelboard
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Breaking Capacity Code:
J
Ambient Air Temperature For Operation:
50 °C
Local Signalling:
trip indicator
Trip Unit Technology:
thermal-magnetic
Circuit Breaker Application:
HACR rated || HID rated
[Ue] Rated Operational Voltage:
480Y/277 V AC
Catalog:
View
Datasheet:
View
$1,630.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 50A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 50 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.